2006
DOI: 10.1016/j.sna.2005.08.009
|View full text |Cite
|
Sign up to set email alerts
|

A high-accuracy, high-speed interface circuit for differential-capacitance transducer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2006
2006
2016
2016

Publication Types

Select...
5
1
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 11 publications
0
9
0
1
Order By: Relevance
“…The measuring section is a quartz glass pipe of length 1.20m, and its inner and outer diameters are 96mm and 100mm. The capacitance measuring circuit is a C/V (capacitance to voltage) conversion circuit, an excitation voltage with 1MHz frequency and 3.3V amplitude are used [23]. 2-electrode and 4-electrode are studied in experimental part, each electrode is scattered evenly around the insulating wall.…”
Section: Resultsmentioning
confidence: 99%
“…The measuring section is a quartz glass pipe of length 1.20m, and its inner and outer diameters are 96mm and 100mm. The capacitance measuring circuit is a C/V (capacitance to voltage) conversion circuit, an excitation voltage with 1MHz frequency and 3.3V amplitude are used [23]. 2-electrode and 4-electrode are studied in experimental part, each electrode is scattered evenly around the insulating wall.…”
Section: Resultsmentioning
confidence: 99%
“…The circuit adopts an excitation voltage with 1V amplitude and 1 MHZ carrier. Then a DSP with 2-channel 18-bit ADC is used for logic control and data processing [30]. With digital data, the medium spatial distribution can be obtained through reconstruction algorithm.…”
Section: The Construction Of Ect Systemmentioning
confidence: 99%
“…[25] It consists of a current detector with a capacitor-array, a precision rectifier circuit, and a second-order low-pass filter, which acted as the amplitude modulation modulator and demodulator, respectively. An excitation voltage with 1 MHz carrier frequency and 1 V amplitude was used.…”
Section: Measurement Circuit and Data Processing Systemmentioning
confidence: 99%
“…A digital signal processor with a two-channel 18-bit analog-to-digital converter was used for data processing and logic control. [25] The capacitance value of each coupled electrode and the average capacitance value were measured by the circuit. …”
Section: Measurement Circuit and Data Processing Systemmentioning
confidence: 99%