2003
DOI: 10.1016/s0168-583x(03)01515-5
|View full text |Cite
|
Sign up to set email alerts
|

A high-power electron linear accelerator for food irradiation applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…One of the major advances has been the continual increase in available dose sensitivity within the megavoltage as well as kilovoltage range. Products such as FWT-60 radiochromic film produced by Far West technologies (Young et al 1999) provide accurate x-ray dosimetry for doses in the kGy range (Miller et al 2003), and products such as Gafchromic MD-55-2 and HS provide accurate dosimetry within the few Gy to 100 Gy region. Radiochromic films have also been developed for increased sensitivity in the lower kVp range (Giles and Murphy 2002) for dosimetry purposes in diagnostic procedures.…”
Section: Introductionmentioning
confidence: 99%
“…One of the major advances has been the continual increase in available dose sensitivity within the megavoltage as well as kilovoltage range. Products such as FWT-60 radiochromic film produced by Far West technologies (Young et al 1999) provide accurate x-ray dosimetry for doses in the kGy range (Miller et al 2003), and products such as Gafchromic MD-55-2 and HS provide accurate dosimetry within the few Gy to 100 Gy region. Radiochromic films have also been developed for increased sensitivity in the lower kVp range (Giles and Murphy 2002) for dosimetry purposes in diagnostic procedures.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the extensive application of the industrial irradiation accelerator [1][2][3], Institute of High Energy Physics (IHEP) is in the process of machining a 325 MHz bi-periodic on-axis coupled accelerating prototype, trying to verify the feasibility of an extremely high average beam power electron linear accelerator. The main specifications of the industrial accelerator are summarized in Table 1.…”
Section: Introductionmentioning
confidence: 99%
“…Radiochromic film dosimetry in radiation detection can depend on many parameters. Some of the major contributing factors can of course be the type of radiochromic film used, such as Gafchromic (ISP Technologies) (Butson et al 2003), Radiachromic (FWT Technologies) (Young et al 1999) or B3 windose (GEX Corporation) (Miller et al 2003). One of the largest contributing factors is the visible absorption spectra of the radiochromic film and as such the wavelength of readout.…”
Section: Introductionmentioning
confidence: 99%