1997
DOI: 10.1086/312976
|View full text |Cite
|
Sign up to set email alerts
|

A High‐Resolution18O Isotope Study in the Vacuum Ultraviolet of theA1Π →X1Σ+4th Positive System of CO

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

3
22
0

Year Published

2000
2000
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(25 citation statements)
references
References 25 publications
3
22
0
Order By: Relevance
“…Our new measurements, with uncertainties between about 0.001 and 0.02 cm −1 , enable the determination of more constants defining the A(0) and perturber levels than previously, and with better precision. All comparable parameters show consistency between this work and that of Beaty et al [12], given their estimated uncertainties, apart from the A(0) and d(4) term origins and the η A(0) ∼ d (4) interaction parameter. The T v discrepancies likely arise from correlation of this parameter with high-order rotational constants and our inclusion of an additional constant, H, relative to Beaty et al [12].…”
Section: Perturbation Analysissupporting
confidence: 89%
See 3 more Smart Citations
“…Our new measurements, with uncertainties between about 0.001 and 0.02 cm −1 , enable the determination of more constants defining the A(0) and perturber levels than previously, and with better precision. All comparable parameters show consistency between this work and that of Beaty et al [12], given their estimated uncertainties, apart from the A(0) and d(4) term origins and the η A(0) ∼ d (4) interaction parameter. The T v discrepancies likely arise from correlation of this parameter with high-order rotational constants and our inclusion of an additional constant, H, relative to Beaty et al [12].…”
Section: Perturbation Analysissupporting
confidence: 89%
“…However, this statistical uncertainty is smaller than the 0.001 cm −1 absolute frequency uncertainty of our data (tied to the REMPI-laser experiment) and we conclude that the estimated uncertainty of T 0 is 0.001 cm −1 . We list all residual differences of laser-measured and modelled frequencies in Table 1 [12] based on comprehensive emission spectra of A−X(0, 0) and extra lines from perturbing states, with their deperturbed constants also listed in Table 7. A similar scale of experimental information was used in that previous work but with frequency uncertainties of 0.05 cm −1 or more.…”
Section: Perturbation Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…Tunable picosecond lasers have been used to measure lifetimes in the E'IIt; = 0 and v = 1 states of three isotopic varieties of CO (Cacciani et al 1998). High-resolution spectroscopy has been performed on the A-X system in 1 2 C 1 8 0 (Beaty et al 1997). The EUV spectrum of CO excited by electron impact has been studied at high resolution (Ciocca, Kanik & Ajello 1997), as well as the A-X system (Beegle et al 1999).…”
Section: Electronic Spectramentioning
confidence: 99%