2021
DOI: 10.1016/j.bioelechem.2020.107718
|View full text |Cite
|
Sign up to set email alerts
|

A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 60 publications
0
10
0
Order By: Relevance
“…The sensitivity is calculated to be 25.74 mA mM –1 cm –2 in a wide linear range of 180 nM to 4.8 μM and 8.75 mA mM –1 cm –2 in 10– 410 μM, along with a LOD of 0.32 nM. The LOD is obtained by the equation LOD = 3 S b /slope, where S b represents the standard deviation calculated by 10 measurements of PBA/MIL-53­(NiFe)/NF under a blank signal, and the slope value is obtained from the calibration plot. , These results are far superior to previous MIL-based and PBA-based electrode materials, as shown in Table S1, where previously related reported literature studies have been summarized. …”
Section: Resultsmentioning
confidence: 91%
“…The sensitivity is calculated to be 25.74 mA mM –1 cm –2 in a wide linear range of 180 nM to 4.8 μM and 8.75 mA mM –1 cm –2 in 10– 410 μM, along with a LOD of 0.32 nM. The LOD is obtained by the equation LOD = 3 S b /slope, where S b represents the standard deviation calculated by 10 measurements of PBA/MIL-53­(NiFe)/NF under a blank signal, and the slope value is obtained from the calibration plot. , These results are far superior to previous MIL-based and PBA-based electrode materials, as shown in Table S1, where previously related reported literature studies have been summarized. …”
Section: Resultsmentioning
confidence: 91%
“…• SPCE/PB: 12 SPCE is immersed in a saturated Na 2 CO 3 solution and amperometrically scanned for 300 s at 1.20 V to remove contamination from the electrode surface. SPCE is immersed in a mixture containing 2.0 mM FeCl 3 , 2.0 mM K 3 Fe (CN) 6 , 0.1 M KCl, and 20 mM HCl.…”
Section: Sample Collectionmentioning
confidence: 99%
“…Electrochemical sensors and biosensors are used in various fields, such as health, environmental monitoring, and food analysis, due to their high sensitivity, rapid response times, and cost-effectiveness. Enzymatic biosensors rely on enzymes as sensitive components for biomolecular recognition . Amperometry is a common technique that measures changes in current under a fixed potential, which is directly proportional to analyte concentration. , Enzymatic biosensors typically exhibit excellent selectivity in practical applications due to the natural specificity of enzymes.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“… 112 As a result, patient-friendly, minimally invasive, or non-invasive fluorescence detection technologies have attracted interest, and some have made significant advances when combined with nanotechnology. The majority of these nanobiosensors are enzymatic or non-enzymatic and are based on the chemisorption of highly active glucose oxidase (GOx) onto AuNPs; 113 or by the chemical coating of different active components into carbon-based electrodes, such as high-purity TiO 2 , 114 silver (Ag) 115 or nickel (Ni) 116 in the nanoscale, among others.…”
Section: Current Development Of Selenium Nanomaterials In Biosensing ...mentioning
confidence: 99%