2021
DOI: 10.1109/access.2021.3058136
|View full text |Cite
|
Sign up to set email alerts
|

A Hybrid Nearest Level Combined With PWM Control Strategy: Analysis and Implementation on Cascaded H-Bridge Multilevel Inverter and its Fault Tolerant Topology

Abstract: This paper presents a hybrid control strategy which combines the nearest level control technique with PWM control technique on a cascaded H-Bridge Multilevel Inverters (MLI). MLIs have become very popular due to its several adavantages in the application areas like industrial drives and gridconnected renewable energy generation systems. With the reduced number of switches, driver circuits, conduction losses, switching losses, voltage stresses, size, and cost of the system, MLI has outperformed its two-level co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
26
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 41 publications
(36 citation statements)
references
References 38 publications
0
26
0
Order By: Relevance
“…In addition, this topology recommends to employ a tap‐changing transformer at inverter output to maintain rated voltage, but this deals with high cost and reduced power density. An asymmetrical MLI topology developed in Sarwar et al 35 employs two redundant switches to make the circuit fault‐tolerant, which can handle all single switch faults and some multiswitch faults. However, the total standing voltage (TSV) requirement in this circuit is very high and necessitates the use of separate DC sources.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, this topology recommends to employ a tap‐changing transformer at inverter output to maintain rated voltage, but this deals with high cost and reduced power density. An asymmetrical MLI topology developed in Sarwar et al 35 employs two redundant switches to make the circuit fault‐tolerant, which can handle all single switch faults and some multiswitch faults. However, the total standing voltage (TSV) requirement in this circuit is very high and necessitates the use of separate DC sources.…”
Section: Introductionmentioning
confidence: 99%
“…(a) High switching frequency modulation (b) Low or Fundamental switching frequency modulation. Substantial power loss occurs in the switches when the inverter is operated at a high switching frequency [6]. Hence the fundamental switching frequency scheme is preferred in high power utilities to minimize the power loss associated with the switching.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, the later developed topologies outperform the three traditional topologies in component counts. Currently, researchers are developing MLIs with an application-based approach with fault-tolerance, modularity, efficiency and even weight and volume requirements in mind [5][6][7].…”
Section: Introductionmentioning
confidence: 99%