A kind of new type photoresponsive molecularly imprinted electrochemical sensor based on 5-[(4-(methacryloyloxy)phenyl)diazenyla]isophthalic acid for the detection of carbaryl

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 54 publications
0
2
0
Order By: Relevance
“…This proposed sensor showed a lower limit of detection compared to other previously reported sensors for carbaryl detection. ,,, Furthermore, several platform types for carbaryl detection displayed a lower limit of detection , due to higher conductivity of the platform materials. Nevertheless, this proposed sensor exhibited a wider linear range of carbaryl detection compared to other modified electrodes. ,, The advantage of this proposed sensor for carbaryl detection includes a lower limit of detection and a wider linear range of concentration that could be attributed to the electrocatalytic activity of gold nanorod-modified SPCE.…”
Section: Resultsmentioning
confidence: 70%
See 1 more Smart Citation
“…This proposed sensor showed a lower limit of detection compared to other previously reported sensors for carbaryl detection. ,,, Furthermore, several platform types for carbaryl detection displayed a lower limit of detection , due to higher conductivity of the platform materials. Nevertheless, this proposed sensor exhibited a wider linear range of carbaryl detection compared to other modified electrodes. ,, The advantage of this proposed sensor for carbaryl detection includes a lower limit of detection and a wider linear range of concentration that could be attributed to the electrocatalytic activity of gold nanorod-modified SPCE.…”
Section: Resultsmentioning
confidence: 70%
“…This proposed sensor showed a lower limit of detection compared to other previously reported sensors for carbaryl detection. 13 , 97 , 98 , 103 Furthermore, several platform types for carbaryl detection displayed a lower limit of detection 96 , 100 due to higher conductivity of the platform materials. Nevertheless, this proposed sensor exhibited a wider linear range of carbaryl detection compared to other modified electrodes.…”
Section: Resultsmentioning
confidence: 99%