A larger statistical basis and a wider application area of the PMV equation in the Fanger model: application area of the PMV equation

Abstract: For sedentary activities, the PMV equation, derived by Fanger, is mainly based on the research of Nevins et al. (720 test subjects). Nevins' experiments were later on repeated by Fanger, but with 128 college-age Danish subjects and 128 elderly Danish subjects, instead of American subjects. Rohles did the research from Nevins et al. again, but over a more extensive temperature range and more, namely 1600, test subjects. Rohles' research results have been partly included in the derivation of the PPD equation, bu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…1. a second-skin façade, thermal activation of floor and ceiling, constant floor temperature of 23°C during working hours and 15 hours after working hours, constant ceiling temperature of 23°C during working hours, Central Government Real Estate Agency guideline criterion, PMV calculated in accordance with NEN-EN-ISO 7730 [2] 2. as 1, however PMV calculated in accordance with [14] 3. as 2, but no cooling of the inlet air and no ceiling cooling, a constant floor temperature of 21°C 4. as 3, but a constant floor temperature of 20°C…”
Section: Variant Calculationsmentioning
confidence: 84%
See 4 more Smart Citations
“…1. a second-skin façade, thermal activation of floor and ceiling, constant floor temperature of 23°C during working hours and 15 hours after working hours, constant ceiling temperature of 23°C during working hours, Central Government Real Estate Agency guideline criterion, PMV calculated in accordance with NEN-EN-ISO 7730 [2] 2. as 1, however PMV calculated in accordance with [14] 3. as 2, but no cooling of the inlet air and no ceiling cooling, a constant floor temperature of 21°C 4. as 3, but a constant floor temperature of 20°C…”
Section: Variant Calculationsmentioning
confidence: 84%
“…• The evaluation of the thermal indoor climate in the office space, on an annual basis, shows a significant difference if the PMV is calculated in accordance with NEN-EN-ISO-7730 or in accordance with the proposal, as done by Roelofsen et al [14] (see variant 1 and 2 in table 2). For an explanation of why this is the case, see [14] . In short, it means that the NEN-EN-ISO 7730 model [2] overestimates the temperature sensation in non-air-conditioned buildings [17] .…”
Section: Discussionmentioning
confidence: 99%