2021
DOI: 10.1016/j.jchromb.2021.122740
|View full text |Cite
|
Sign up to set email alerts
|

A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based assay for simultaneous quantification of aldosterone, renin activity, and angiotensin II in human plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
20
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(21 citation statements)
references
References 29 publications
1
20
0
Order By: Relevance
“…Apart from conventional HPLC, other sophisticated HPLC-based techniques have been widely applied for the determination of pharmaceuticals, including antibiotics in various samples. The referred methods include liquid chromatography—mass spectrometry (LC-MS) [ 49 , 50 ], ultra-high performance liquid chromatography-MS/MS (UHPLC-MS/MS) [ 51 , 52 , 53 ], and liquid chromatography linked to tandem mass spectrometry (LC-MS/MS) [ 54 , 55 ].…”
Section: Methods Used To Analyze Antibioticsmentioning
confidence: 99%
“…Apart from conventional HPLC, other sophisticated HPLC-based techniques have been widely applied for the determination of pharmaceuticals, including antibiotics in various samples. The referred methods include liquid chromatography—mass spectrometry (LC-MS) [ 49 , 50 ], ultra-high performance liquid chromatography-MS/MS (UHPLC-MS/MS) [ 51 , 52 , 53 ], and liquid chromatography linked to tandem mass spectrometry (LC-MS/MS) [ 54 , 55 ].…”
Section: Methods Used To Analyze Antibioticsmentioning
confidence: 99%
“…Until the newly LC–MS/MS assays were continuously developed for PRA determination, they followed the main inhibitor regimen of RIA, in which EDTA, PMSF, SBTI, and neomycin were retained for the protection of Ang1 17 . Recently, the incubation time was cut to 3 h, and neomycin (for inhibition of bacterial peptidase during longer incubation 85 ) was less used in routine laboratories 64 . Therefore, the combination of EDTA, PMSF, and SBTI was chosen as the recommended inhibitors for LC–MS/MS analysis.…”
Section: Factors Affecting the Pra Measurement Processmentioning
confidence: 99%
“…First, for high PRA samples, sufficient incubation could reduce the proportion of blanks and make the blanks negligible. Second, some studies demonstrated that the blanks are usually below the LLOQ, and blank measurement causes sample consumption and labor costs because larger sample volumes are required for two analyses 50,52,62,64 . Samples with endogenous Ang1 above the LLOQ accounted for only 5.6%–8.5% of the generated Ang1 60,64 .…”
Section: Factors Affecting the Pra Measurement Processmentioning
confidence: 99%