A low-cost, portable, two-dimensional bioimpedance distribution estimation system based on the AD5933 impedance converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 42 publications
0
6
0
Order By: Relevance
“…On the other hand, the results of [34] indicate that a healthy knee exhibits an impedance between 260 and 360 Ohms at a frequency of 50 kHz, and a 5% decrease in knee impedance suggests joint injury. In-vitro tests reveal that the BIM system can measure impedances ranging from 155 to 977 Ohms [33], establishing its suitability for conducting KOA studies.…”
Section: Measurement Devicementioning
confidence: 98%
See 1 more Smart Citation
“…On the other hand, the results of [34] indicate that a healthy knee exhibits an impedance between 260 and 360 Ohms at a frequency of 50 kHz, and a 5% decrease in knee impedance suggests joint injury. In-vitro tests reveal that the BIM system can measure impedances ranging from 155 to 977 Ohms [33], establishing its suitability for conducting KOA studies.…”
Section: Measurement Devicementioning
confidence: 98%
“…Bioimpedance measurements (BIM) were conducted using a custom-designed eight-channel electronic prototype previously developed [33] (figure 1). The BIM system incorporates an AD5933 impedance converter, which generates a 50 kHz alternating voltage signal.…”
Section: Measurement Devicementioning
confidence: 99%
“…Two recently published articles from the university of Cauca propose a more complete open source systems, but feature, respectively, 8 electrodes [18] , and 4 rings of 8 electrodes [19] limiting the achievable in-plane imaging resolution.…”
Section: Hardware In Contextmentioning
confidence: 99%
“…Since the value of the capacitance C affects the switching frequency of the signal V 2 but does not affect the linearity of the achieved characteristics, the results of the simulations are reported for the case C = 60 nF. Under these conditions, the resistance R 2 must comply with the constraints defined by Equations ( 5) and (10), and thus,…”
Section: Digitalmentioning
confidence: 99%
“…These systems are usually based on microcontrollers and/or Field Programmable Gate Arrays (FPGAs) and are powered by batteries [1] or scavenge energy from natural sources [2]. The sensing applications cover a wide range of fields, such as environmental monitoring [3][4][5], food screening for quality analysis and safety [6][7][8], biological measurements for human body composition determination and health monitoring [9][10][11], bacterial detection [12][13][14], chemical analysis [15][16][17], health monitoring, and data collection on civil infrastructures [18][19][20].…”
Section: Introductionmentioning