A Method for Measuring the Volume of Transdermally Extracted Interstitial Fluid by a Three-Electrode Skin Resistance Sensor

Abstract: It is difficult to accurately measure the volume of transdermally extracted interstitial fluid (ISF), which is important for improving blood glucose prediction accuracy. Skin resistance, which is a good indicator of skin permeability, can be used to determine the volume of extracted ISF. However, it is a challenge to realize in vivo longitudinal skin resistance measurements of microareas. In this study, a three-electrode sensor was presented for measuring single-point skin resistance in vivo, and a method for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…The longitudinal skin resistance of the ultrasonic area on the skin develops vertical micropores and good permeability, but it is also difficult to measure the longitudinal skin resistance precisely. [ 61 ] Thus, the application of this technique has been very limited, and further studies are required for successful and repeated extraction of ISF. Generally, almost no pain is associated with this method, but the patient may experience slight heating of the skin during the process.…”
Section: Current Isf Sampling Methodsmentioning
confidence: 99%
“…The longitudinal skin resistance of the ultrasonic area on the skin develops vertical micropores and good permeability, but it is also difficult to measure the longitudinal skin resistance precisely. [ 61 ] Thus, the application of this technique has been very limited, and further studies are required for successful and repeated extraction of ISF. Generally, almost no pain is associated with this method, but the patient may experience slight heating of the skin during the process.…”
Section: Current Isf Sampling Methodsmentioning
confidence: 99%
“…Normal skin impedance was proven to be an important indicator of skin permeability (19). Therefore, normal skin impedance experiments were conducted firstly to verify the possibility of the proposed thermal activation method by a noninvasive three-electrode measurement method (20). The measurement method, setup, and data are shown in figs.…”
Section: Thermal Activation To Facilitate Isf Extractionmentioning
confidence: 99%
“…Under low frequency conditions (100 Hz~1000 Hz), skin impedance can better reflect its penetration. The smaller the impedance of skin becomes, the greater the penetration of skin becomes [ 11 , 12 , 13 ]. Traditionally, skin permeability evaluation, which is realized by impedance detected at a certain frequency based on macro-electrode, has the disadvantages of large measurement error, low sensitivity, and difficulty in integration [ 14 , 15 ].…”
Section: Introductionmentioning