2001
DOI: 10.1101/gr.gr1644r
|View full text |Cite
|
Sign up to set email alerts
|

A Method For Parallel, Automated, Thermal Cycling of Submicroliter Samples

Abstract: A large fraction of the cost of DNA sequencing and other DNA-analysis processes results from the reagent costs incurred during cycle sequencing or PCR. In particular, the high cost of the enzymes and dyes used in these processes often results in thermal cycling costs exceeding $0.50 per sample. In the case of high-throughput DNA sequencing, this is a significant and unnecessary expense. Improved detection efficiency of new sequencing instrumentation allows the reaction volumes for cycle sequencing to be scaled… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2001
2001
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…Besides, 1000-fold parallelism is another great problem in handling such a minute volume of solution even if robotics could be employed. This has been a common challenge for MEMS (mechano-electro micro system) and μTAS (micro-Total Analysis System) approaches [13-15,27,28], but yet not completely solved. Therefore, a direct transfer, aperture-to-aperture (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Besides, 1000-fold parallelism is another great problem in handling such a minute volume of solution even if robotics could be employed. This has been a common challenge for MEMS (mechano-electro micro system) and μTAS (micro-Total Analysis System) approaches [13-15,27,28], but yet not completely solved. Therefore, a direct transfer, aperture-to-aperture (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, technologies dealing with less than μL aliquots have been pursued. Although there are not a few studies on dealing with sub-μL solutions [13-15], they are basically microfluidics approaches and are currently limited in the degree of parallelism and the number of possible reaction steps [16]. This may be because they are adopting, in a sense, a closed system so as to prevent from evaporation-loss of a tiny volume of sample, leading to rather elaborate and complicated systems.…”
Section: Introductionmentioning
confidence: 99%
“…New PCR instruments that use microcapillaries instead of microtitre plate formats have been devised, and offer increased PCR throughput and reduced reagent costs as they use extremely short amplification times and small reaction volumes 121,122 . Fully automated SNP analysis systems could then be designed based on homogeneous detection, or by streamlining the PCR and the subsequent genotyping procedure in microfluidic 'lab chip' devices that operate with submicrolitre reaction volumes.…”
Section: Ligation Methodsmentioning
confidence: 99%
“…Top performance of a non-contact dispensing system can achieve throughput up to 96 samples in a few minutes and sub-nanoliter precision, with 4-8 tips pipetting simultaneously. [12][13][14] Other methods include dip-pen nanolithography technique and polymer pen lithography, 15,16 where nanoscale tips were used to write liquid patterns directly on a substance with different kinds of inks. Impressive results have been claimed, e.g.…”
Section: Introductionmentioning
confidence: 99%