1988
DOI: 10.1111/j.1365-2842.1988.tb00149.x
|View full text |Cite
|
Sign up to set email alerts
|

A method for standardization of silent period measurements in human masseter muscle

Abstract: The effect of bite force and stimulus intensity on the electrically induced SP has been studied. The results from the present study and earlier investigations suggest that the following guidelines should be used in future SP studies. (i) The electrical rather than mechanical way of stimulation should be preferred since the stimulus parameters and the receptors stimulated can easily be determined. (ii) The sensory perception threshold (T) of subjects should be used when studying and comparing the SP between ind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
15
1
1

Year Published

1994
1994
2008
2008

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(20 citation statements)
references
References 37 publications
3
15
1
1
Order By: Relevance
“…The latencies varied between 12.5 and 12.9 ms and were similar to the latencies elicited in other studies by a menton tap (Ciancaglini et al, 1989;Karkazis and Kossioni, 1999;Kossioni and Karkazis, 1995a,b, 1998, but were shorter than the latencies of SPs elicited by electrical stimulation of the tooth pulp (Sharav et al, 1982), the lower lip (20 ms) (Tü rker, 1988;Tü rker and Miles, 1985) or by mechanical stimulation of the hard palate (50 ms) (Di Francesco et al, 1986) and the skin over the masseter muscle (54 ms) (Yemm, 1972). Due to the short latency in DI group (Table 1), the reflex may be considered to be olygosynaptic.…”
Section: Discussionsupporting
confidence: 77%
See 2 more Smart Citations
“…The latencies varied between 12.5 and 12.9 ms and were similar to the latencies elicited in other studies by a menton tap (Ciancaglini et al, 1989;Karkazis and Kossioni, 1999;Kossioni and Karkazis, 1995a,b, 1998, but were shorter than the latencies of SPs elicited by electrical stimulation of the tooth pulp (Sharav et al, 1982), the lower lip (20 ms) (Tü rker, 1988;Tü rker and Miles, 1985) or by mechanical stimulation of the hard palate (50 ms) (Di Francesco et al, 1986) and the skin over the masseter muscle (54 ms) (Yemm, 1972). Due to the short latency in DI group (Table 1), the reflex may be considered to be olygosynaptic.…”
Section: Discussionsupporting
confidence: 77%
“…Although some authors attribute SP eliciting mainly to periodontal receptors' stimulation and/or muscle unloading, it is possible that other receptors play a role in that process (Alajbeg et al, 2005;Bessette et al, 1971;Brenman et al, 1968;Brodin et al, 1991;Cadden and Newton, 1992;Chong-Shan and Hui-Yun, 1989;Ciancaglini et al, 1989;Dessem et al, 1988;Freesmeyer, 1987;Di Francesco et al, 1986;Griffin and Munro, 1971;Jacobs and van Steenberghe, 2006;Karkazis, 1998, 1999;De Laat et al, 1985;Lavigne et al, 1983;Schaerer et al, 1967;Tallgren et al, 1987;Tü rker andMiles, 1985, 1989;Tü rker et al, 1994;Tü rker and Jenkins, 2000;Yoshida, 1998;Widmalm and Hedegard, 1976;Widmalm and Ash, 1985;Yemm, 1972).…”
Section: Introductionmentioning
confidence: 97%
See 1 more Smart Citation
“…Multiunit and single MU recordings have been made in many human studies and most often analyzed by averaging techniques (e.g., Cadden and Newton, 1989;Turker etal, 1989). The validity of multiunit electromyography as a method for measuring jaw reflex activity can be disputed (Lavigne etal, 1983;Turker, 1988). The relative position of the stimulus during repetitive MU activity, MU firing rate, and the task performed are all known to affect reflex inhibition in the human jaw muscles, and MU synchronization can be misinterpreted as an apparent excitatory response when averaging techniques are used (Widmer and Lund, 1989).…”
Section: Reflex Behaviormentioning
confidence: 98%
“…Usually, the sensory perception threshold (T) of the subject is used to standardize the stimulus intensity rather than the actual voltage or the current delivered (Türker, 1988). Intensities of 1-3 T are used to stimulate lowthreshold afferents which convey information about touch…”
Section: Mucosa and Skin Stimulationmentioning