2004
DOI: 10.1016/j.apradiso.2004.03.024
|View full text |Cite
|
Sign up to set email alerts
|

A method for the determination of low-level organic-bound tritium activities in environmental samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0
2

Year Published

2005
2005
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(17 citation statements)
references
References 22 publications
0
15
0
2
Order By: Relevance
“…The tritium concentration in environmental samples is normally very low (< 1 mBq/ml), the LSC is therefore not sensitive enough for the directly measurement, an electrolytic method is therefore often applied to enrich tritium from water [121], the enrichment factor of 30-100 can easily be obtained for 100-500 ml water. For the determination of tritium in solid samples, a combustion method is used to convert tritium to THO, which subsequently is measured by LSC [120][121][122].…”
Section: Tritiummentioning
confidence: 99%
“…The tritium concentration in environmental samples is normally very low (< 1 mBq/ml), the LSC is therefore not sensitive enough for the directly measurement, an electrolytic method is therefore often applied to enrich tritium from water [121], the enrichment factor of 30-100 can easily be obtained for 100-500 ml water. For the determination of tritium in solid samples, a combustion method is used to convert tritium to THO, which subsequently is measured by LSC [120][121][122].…”
Section: Tritiummentioning
confidence: 99%
“…Cette fraction est extraite par combustion dans un four tubulaire de diamètre suffisant pour le traitement d'échantillons de masse élevée (jusqu'à 40 g) afin de récupérer la masse d'eau de combustion nécessaire à une mesure optimale par scintillation liquide (Pointurier et al, 2004 ;Baglan et al, 2005). Une photo du four utilisé est présentée en figure 2.…”
Section: Extraction Du Tritium Organiquement Lié Non éChangeable (Tolunclassified
“…La technique de référence utilisée couramment en routine pour l'analyse du tritium est la scintillation liquide (Theodorsson, 1999 ;Cassette, 2004 ;Pointurier et al, 2004) permettant de mesurer des concentrations de l'ordre de quelques Bq.L -1 pour les compteurs bas bruit de fond.…”
Section: Techniques D'analyseunclassified
“…OBT/HTO ratios in terrestrial plants and food items are often substantially greater than one, even far away from local tritium sources: for samples representative of "background" environmental conditions, the mean OBT/HTO value is close to 2 (Pointurier et al, 2004;Baglan et al, 2005), with measured values sometimes up to 3 or 4 (Jean-Baptiste et al, 2011). This tritium enrichment has often been attributed to soil moisture with presumably lower tritium content than atmospheric water vapour.…”
Section: Variable Obt/hto Ratio In the Aquatic Environment (E Fourrémentioning
confidence: 99%