Abstract:The identification of model damping is a key for response analysis. A method is presented for updating damping of the computational model of substructure based on frequency response experiment. The proposed method directly identifies mass, stiffness and damping matrices by using the substructure error coefficient and frequency response experiment, then computational model damping is updated, finally the effectiveness of the method with simulated data gauging is studied in this paper.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.