2013
DOI: 10.4028/www.scientific.net/amr.721.392
|View full text |Cite
|
Sign up to set email alerts
|

A Method of Improving Signal Capture Ability of Digital Oscilloscope

Abstract: Signal capture is one of the hot spots in electronic test. As the representative of testing instrument, the signal capture ability of digital oscilloscope is normally judged by the waveform capture rate. Unilaterally improving signal acquisition ability whereas ignoring the improvement of waveform imaging mechanism and display effect can not increase the oscilloscopes waveform capture rate in real sense. Aiming at better ability of signal acquisition and waveform display effect of oscilloscope, this paper is c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 3 publications
0
2
0
Order By: Relevance
“…Through testing for many times, can be displayed on the oscilloscope and 8 digital signal sequence, can adjust 8-way digital signal timing the triggering time of the waveform, can choose different trigger mode, can add the manual displacement time marker on the screen, with eight LED display time line 8 digital signals of corresponding time status, to 8 road logic state of the digital signal acquisition and storage, and on the oscilloscope playback two displacement cycle 8-way digital signal. However, there are some individual display waveforms and manual cursor display that cannot achieve absolute "horizontal, horizontal and vertical", because the D/A conversion output has A certain drift, and the D/A conversion output cannot achieve absolute linearity [6] .…”
Section: The Test Results and Analysismentioning
confidence: 99%
“…Through testing for many times, can be displayed on the oscilloscope and 8 digital signal sequence, can adjust 8-way digital signal timing the triggering time of the waveform, can choose different trigger mode, can add the manual displacement time marker on the screen, with eight LED display time line 8 digital signals of corresponding time status, to 8 road logic state of the digital signal acquisition and storage, and on the oscilloscope playback two displacement cycle 8-way digital signal. However, there are some individual display waveforms and manual cursor display that cannot achieve absolute "horizontal, horizontal and vertical", because the D/A conversion output has A certain drift, and the D/A conversion output cannot achieve absolute linearity [6] .…”
Section: The Test Results and Analysismentioning
confidence: 99%
“…A waveform generator 11 (33500B series, Keysight) was applied as a pulse generator to excite the ultrasonic sensor to produce the corresponding ultrasonic pulse wave. A digital oscilloscope 12 (RTB2000, Rohde & Schwarz) was used to collect the ultrasonic signal of the sensor and upload it to the computer for further analysis.…”
Section: Experimental Devicesmentioning
confidence: 99%