2020
DOI: 10.1016/j.epsr.2020.106268
|View full text |Cite
|
Sign up to set email alerts
|

A methodology for imposing harmonic distortion's penalty in customers bill

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…Up to now, various methods have been proposed, to determine the amount of the penalty. Some of these methods are based on the estimation of the cost of harmonic damages to penalize harmonic sources [1,14,[18][19][20]. Another set of methods seeks pricing through the determination of the HCC [8,21], which have better computability and are more reasonable for the HSs compared to the first group methods.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Up to now, various methods have been proposed, to determine the amount of the penalty. Some of these methods are based on the estimation of the cost of harmonic damages to penalize harmonic sources [1,14,[18][19][20]. Another set of methods seeks pricing through the determination of the HCC [8,21], which have better computability and are more reasonable for the HSs compared to the first group methods.…”
Section: Introductionmentioning
confidence: 99%
“…Previous models for harmonic penalty calculations presented in literature, have directly used the current measured at the PCC of customer to determine the penalty [18, 19]. However, for example when a linear load is fed from the polluted bus, the current measured at PCC of that load also contains harmonic currents which in turn, causes an important error in calculating the penalty of that load.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Power utilities need to investigate a penalty fee that needs to be charged for harmonic distortion. This fee is to be part of the monthly electricity bill as an added investment to reduce the financial losses met due to the effects of harmonic distortion [1,[24][25][26].…”
Section: Introductionmentioning
confidence: 99%
“…Several publications investigate the effects of harmonics on the losses and/or life expectancy of the motors, transformers, and cables, for instance. Some examples can be founded in [174][175][176][177][178][179][180][181][182]. In [183], the authors investigate some of known lossreduction methods in the feeder.…”
Section: Impacts On the Harmonic Power Lossesmentioning