2014
DOI: 10.1016/j.buildenv.2013.10.015
|View full text |Cite
|
Sign up to set email alerts
|

A methodology for the study of the acoustic environment of Catholic cathedrals: Application to the Cathedral of Malaga

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
52
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 49 publications
(52 citation statements)
references
References 26 publications
0
52
0
Order By: Relevance
“…Desarnaulds et al took acoustic measurements at six churches and analysed speech intelligibility in the churches under the field conditions (both occupied and unoccupied) [21]. Alvarez-Morales et al combined measurement and simulation to understand the acoustic environment of historical churches and analyse the effects of different sound source positions on the acoustic field [22,23]. Orfali and Ahnert measured and analysed the acoustic field parameters in two mosques [24,25].…”
Section: Introductionmentioning
confidence: 99%
“…Desarnaulds et al took acoustic measurements at six churches and analysed speech intelligibility in the churches under the field conditions (both occupied and unoccupied) [21]. Alvarez-Morales et al combined measurement and simulation to understand the acoustic environment of historical churches and analyse the effects of different sound source positions on the acoustic field [22,23]. Orfali and Ahnert measured and analysed the acoustic field parameters in two mosques [24,25].…”
Section: Introductionmentioning
confidence: 99%
“…The acoustic measurements were carried out under unoccupied conditions taking ISO3382-1 [1] as a reference, as well as considering the specific guidelines developed for similar buildings [2,3]. The signal utilised was a 24-second-long sine-sweep emitted through a dodecahedral loudspeaker with a frequency response from 50 Hz to 10 kHz (NTi DS3 loudspeaker together with a NTi PA3 power amplifier) at a height of 1.5 m. The level and the duration of the excitation signal were set to ensure a reliable calculation of T 30, which means that an impulse-to-noise ratio (INR) higher than 45 dB in all octave bands would be achieved, even in those receivers located at the furthest positions from the source (see Figure 4).…”
Section: Acoustic Measurements In the Chapter Housementioning
confidence: 99%
“…The experimental study of the acoustics of the Chapter House was conducted following the well-established methodology outlined in ISO 3382-part 1 [1], as well as additional guidelines developed for churches and cathedrals [2,3]. As in previous studies on cathedral acoustics [4][5][6], a thorough analysis of the acoustic behaviour of the space was conducted through the acoustic parameter values derived from the measured RIR, registered at a set of positions which reflected the wide diversity of uses of the site.…”
Section: Introductionmentioning
confidence: 99%
“…The acoustic parameters of worship interiors are the subject of research and analysis by many scientists (Álvarez-Morales et al, 2014;Berardi et al, 2009; 2015; Berardi, 2014; Engel, Kosała, 2005;Kosała, 2009;Małecki, 2014;Martellotta, 2009;Suárez et al, 2015). Studies show that a large number of churches, especially modern ones, have excessive reverberation, which leads to poor speech intelligibility, poor-quality music playing and listening, and problems with the sound amplification system.…”
Section: Introductionmentioning
confidence: 99%