1997
DOI: 10.1016/s0925-4005(97)00171-8
|View full text |Cite
|
Sign up to set email alerts
|

A micromachined solid state integrated gas sensor for the detection of aromatic hydrocarbons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
25
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 59 publications
(26 citation statements)
references
References 4 publications
1
25
0
Order By: Relevance
“…The µ-THS with the heat spreader has a voltage signal (temperature change ∆T A-B ) response approximately 4 times (3 times respectively) lower than the µ-THS without the heat spreader. The silicon heat spreader is known to improve the gas sensitivity and selectivity because of a better uniformity of the heat distribution in the membrane and also less degradation of the micro-hotplate meander due to hot spots (5) (11) . For the µ-THS, the heat spreader reduces the local temperature distribution around the micro-hotplate and also ∆T A-B resulting in the signal decrease observed in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The µ-THS with the heat spreader has a voltage signal (temperature change ∆T A-B ) response approximately 4 times (3 times respectively) lower than the µ-THS without the heat spreader. The silicon heat spreader is known to improve the gas sensitivity and selectivity because of a better uniformity of the heat distribution in the membrane and also less degradation of the micro-hotplate meander due to hot spots (5) (11) . For the µ-THS, the heat spreader reduces the local temperature distribution around the micro-hotplate and also ∆T A-B resulting in the signal decrease observed in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…An integrated sensor with an array of four microsensor elements was designed using finite element analysis [17] to achieve reduced power consumption, and constructed using microelectronic fabrication technology. The devices were fabricated on double-side polished p-type 1 0 0 Si substrates 300 m thick.…”
Section: Substrate Fabricationmentioning
confidence: 99%
“…In the present case, isolation of the structure from the bonding area has been ensured by setting a lateral air gap of 500 m under the connecting membrane [11]. Pyrex glass has been used to seal the silicon structure in both faces.…”
Section: Description Of the Preconcentrator Structurementioning