2021
DOI: 10.1080/10934529.2021.1881352
|View full text |Cite
|
Sign up to set email alerts
|

A model for phthalic acid esters’ biodegradability and biotoxicity multi-effect pharmacophore and its application in molecular modification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 72 publications
0
4
0
Order By: Relevance
“…With a Dell PowerEdge R7425 server, Groningen Machine for Chemical Simulation (GROMACS, Berendsen Laboratory, Göttingen University, Göttingen, Germany) 4.6.5 was applied to achieve the molecular dynamics simulations of PAHs and toxic receptor complex [ 52 , 53 , 54 ]. The molecular mechanics Poisson–Boltzmann surface area (MM/PBSA) method was used to calculate the binding free energy between PAHs and the toxic receptor complex [ 55 ] ( Table S2 in Supplementary Materials ).…”
Section: Methodsmentioning
confidence: 99%
“…With a Dell PowerEdge R7425 server, Groningen Machine for Chemical Simulation (GROMACS, Berendsen Laboratory, Göttingen University, Göttingen, Germany) 4.6.5 was applied to achieve the molecular dynamics simulations of PAHs and toxic receptor complex [ 52 , 53 , 54 ]. The molecular mechanics Poisson–Boltzmann surface area (MM/PBSA) method was used to calculate the binding free energy between PAHs and the toxic receptor complex [ 55 ] ( Table S2 in Supplementary Materials ).…”
Section: Methodsmentioning
confidence: 99%
“…Using the Minimize module in Sybyl-X 2.0 software, the three-dimensional structures of PAEs were optimized using the Powell conjugate gradient method to obtain the low-energy conformation of each molecule, with selected Gasterger–Hückle charge and Tripos molecular force field. The energy convergence standard and iteration number were set to 0.005 kcal mol −1 and 10,000, respectively [ 31 ].…”
Section: Methodsmentioning
confidence: 99%
“…After docking, the structure of the complex was uploaded to the ATB database for data extraction. Finally, using the GROMACS software, the MD simulation of the complex was performed [60,61], the BE of the complex was calculated [62], and the BE value was used to characterize the interference intensity of PAEs on the hormone receptor proteins [25].…”
Section: Calculation Of the Be Between Paes And Hormone Receptor Prot...mentioning
confidence: 99%
“…The degree of interaction between PAEs and hormone protein receptors was expressed by BE. A smaller BE indicates a stronger binding ability and a greater hormone effect [25]. To more intuitively analyze the ED effects of PAEs and determine the main molecular characteristic values that have a greater impact on their ED effects, the CV of the BE data of the molecular docking between the 22 PAEs and the estrogen protein, androgen protein, and thyroid hormone protein was calculated using the CV method; the CVs were 0.5106, 0.4583, and 0.4458, and the weights were 0.3609, 0.3240, and 0.3151, respectively.…”
Section: Introductionmentioning
confidence: 99%