2001
DOI: 10.1016/s0301-9322(00)00052-5
|View full text |Cite
|
Sign up to set email alerts
|

A modeling of in-tube condensation heat transfer for a turbulent annular film flow with liquid entrainment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
5

Year Published

2014
2014
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 13 publications
0
5
0
5
Order By: Relevance
“…In tab. 2 the calculations of the experimental data from [37] for R22, R134, and R236, from [39] for R22, from [38] for propane, and from [17] for R12 are represented. For different G and q a good convergence of prediction with the experimental data is clearly seen.…”
Section: The Results Of Experimental Studiesmentioning
confidence: 99%
“…In tab. 2 the calculations of the experimental data from [37] for R22, R134, and R236, from [39] for R22, from [38] for propane, and from [17] for R12 are represented. For different G and q a good convergence of prediction with the experimental data is clearly seen.…”
Section: The Results Of Experimental Studiesmentioning
confidence: 99%
“…The total heat transfer coefficient hT is almost the same for the two scenarios. Kwon et al (2001) studied numerically the effect of entrainment for the pure fluid R22 and obtained a prominent enhancement of the heat transfer using the model with entrainment, reaching up to 20% higher heat transfer rates at high mass flux and quality conditions. They also introduced the mechanism that the thinner liquid film thickness causes a larger condensation heat transfer coefficient.…”
Section: Validation Results and Discussionmentioning
confidence: 99%
“…Авторы работы [5] сравнили свою модель рас-чета и экспериментальные данные по конденсации R22 внутри трубы d = 9,5 мм и l = 0,4 м при t s = 40°C для двух значений G (300 и 400 кг/м 2 с). Несмотря на недостаточно четкое влияние потерь на теплоотдачу, как видно из работы [5], модели из [5] и [4], а также корреляции из [12] дают близкие результаты, и при х = 0,06 ÷ 0,8 они согласуются с экспериментами в пределах ± 15%.…”
Section: сравнение теоретических (полу-эмперических) решений с экunclassified
“…Несмотря на недостаточно четкое влияние потерь на теплоотдачу, как видно из работы [5], модели из [5] и [4], а также корреляции из [12] дают близкие результаты, и при х = 0,06 ÷ 0,8 они согласуются с экспериментами в пределах ± 15%. Кроме того, для оценки модели [4] авторы применяют только соотношение (1), которое, очевидно, не обеспечивает сходимость при х > 0,6.…”
Section: сравнение теоретических (полу-эмперических) решений с экunclassified
See 1 more Smart Citation