2014
DOI: 10.1002/rcm.6909
|View full text |Cite
|
Sign up to set email alerts
|

A modified procedure for gas‐source isotope ratio mass spectrometry: the long‐integration dual‐inlet (LIDI) methodology and implications for clumped isotope measurements

Abstract: For traditional and clumped isotope measurements of CO2, the LIDI protocol allows the measurement of a much larger portion of the sample gas rather than only ~20% of it. In addition, the sample can be measured at higher signal intensity and for longer time, allowing the measurement of smaller samples while preserving precision. We suggest that other gases commonly used for stable isotope measurements with gas-source mass spectrometry would also benefit from this new protocol.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
71
0
2

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 61 publications
(74 citation statements)
references
References 32 publications
1
71
0
2
Order By: Relevance
“…In the past, slightly reduced Δ 47 external precision specific to the acid drip method was hypothesized to be a result of atmospheric leakage in the reaction vessel, and/or carbonate heterogeneity more pronounced in 0.200 mg subsamples (Schmid and Bernasconi, 2010). However, recent measurement procedure and correction innovations (e.g., Hu et al, 2014;Meckler et al, 2014) have enabled similar Δ 47 external precision to the McCrea-style reaction vessel and common acid bath methods while reducing total carbonate sample size to 1.5-2.0 mg (or less).…”
Section: Acid Drip Methodsmentioning
confidence: 96%
See 2 more Smart Citations
“…In the past, slightly reduced Δ 47 external precision specific to the acid drip method was hypothesized to be a result of atmospheric leakage in the reaction vessel, and/or carbonate heterogeneity more pronounced in 0.200 mg subsamples (Schmid and Bernasconi, 2010). However, recent measurement procedure and correction innovations (e.g., Hu et al, 2014;Meckler et al, 2014) have enabled similar Δ 47 external precision to the McCrea-style reaction vessel and common acid bath methods while reducing total carbonate sample size to 1.5-2.0 mg (or less).…”
Section: Acid Drip Methodsmentioning
confidence: 96%
“…This protocol consists of a single sample measurement followed by a single reference measurement of ~600 seconds each (Hu et al, 2014). This process negates the requirement of an initial pressure balancing phase as well as the constant flow of sample CO 2 gas to the exhaust pump, effectively enabling the measurement of the bulk of the available sample CO 2 gas.…”
Section: Alternative δ 47 Measurement Protocolsmentioning
confidence: 99%
See 1 more Smart Citation
“…ETH Zürich), vagy más fejlesztésű minta-előkészítő beren dezéshez csatolva a mé rés automatizál -ható, a mintaszám növelhető, a szük sé -ges anyagmennyiség pedig csökkent -hető (PASSEY et al 2010, SCHMID & BERNASCONI 2010, HU et al 2014. GHOSH et al (2006a) 1-50 °C közötti hőmér sékleti tartományra kidolgozott kalibrációja volt az első publikált ∆ 47 -T összefüggés, ami megmutatta, hogy az elméleti összefüggés a gyakorlatban is érvényes.…”
Section: Műszerekunclassified
“…Kiemelt cél a hatékonyság és a precizitás növelése, illetve a szükséges mintamennyiség csökkentése (pl. HE et al 2012, BERNASCONI et al 2013, ROSENHEIM et al 2013, CUI & WANG 2014, HU et al 2014, RÖCKMANN et al 2016. A kalibrációs munkák célja az alkalmazhatóság kiterjesztése szélesebb hőmérsékleti tartományokra (pl.…”
unclassified