2018
DOI: 10.1155/2018/3437149
|View full text |Cite
|
Sign up to set email alerts
|

A Molecularly Imprinted Electrochemical Gas Sensor to Sense Butylated Hydroxytoluene in Air

Abstract: Alzheimer’s disease (AD) is a neurodegenerative disease, which affects millions of people worldwide. Curing this disease has not gained much success so far. Exhaled breath gas analysis offers an inexpensive, noninvasive, and immediate method for detecting a large number of diseases, including AD. In this paper, a new method is proposed to detect butylated hydroxytoluene (BHT) in the air, which is one of the chemicals found in the breath print of AD patients. A three-layer sensor was formed through deposition o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

2019
2019
2025
2025

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 36 publications
0
11
0
1
Order By: Relevance
“…Milli-Q laboratory grade ultrapure water (conductivity <0.1 μS/cm) was used to prepare all solutions, and all buffer solutions were prepared in PBS (1.0 × 10 –2 mol/L, pH 7.36). Potassium hexacyanoferrate III (K 3 [Fe­(CN) 6 ]) and potassium hexacyanoferrate II (K 4 [Fe­(CN) 6 ]) trihydrate were purchased from Riedel-de Häen; PBS was purchased from Amresco; potassium chloride (KCl) and oxalic acid dihydrate were purchased from Merck; ethanol absolute (99.5%) was purchased from PanReac; EDOT 97% was purchased from Alfa Aesar; FBS and ATP 96% were purchased from Acros Organics; β-amyloid human (≥95%) was purchased from GenScript; and trypsin solution 10×, O PDA, BSA, Crea, and Glu were purchased from Sigma-Aldrich.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Milli-Q laboratory grade ultrapure water (conductivity <0.1 μS/cm) was used to prepare all solutions, and all buffer solutions were prepared in PBS (1.0 × 10 –2 mol/L, pH 7.36). Potassium hexacyanoferrate III (K 3 [Fe­(CN) 6 ]) and potassium hexacyanoferrate II (K 4 [Fe­(CN) 6 ]) trihydrate were purchased from Riedel-de Häen; PBS was purchased from Amresco; potassium chloride (KCl) and oxalic acid dihydrate were purchased from Merck; ethanol absolute (99.5%) was purchased from PanReac; EDOT 97% was purchased from Alfa Aesar; FBS and ATP 96% were purchased from Acros Organics; β-amyloid human (≥95%) was purchased from GenScript; and trypsin solution 10×, O PDA, BSA, Crea, and Glu were purchased from Sigma-Aldrich.…”
Section: Methodsmentioning
confidence: 99%
“…Their monomer of choice was aniline, for being stable and easily electropolymerized, much alike phenylenediamine. Emam et al 37 opted for pyrrole, whose electropolymerization conditions are well studied because their MIP-based sensor was very innovative by diagnosing AD in a noninvasive method through the breath of the patient. It is important to highlight that the previously described MIP biosensors, devoted to Aβ-42, may be developed to target other biomarkers circulating in the blood, including Aβ-42 derivatives, most recently established as highly significant in terms of AD.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…With regard to the electrochemical sensing of nonelectroactive targets, redox probes are often used for signal outputs. Redox probes include the frequently used [Fe(CN) 6 ] 3−/2− , 136,138,158,159 Prussian blue (PB), 120,121,135,179 N 2 H 4 ·H 2 O, 173 etc. Wang et al reported a 3D MIP electrochemical sensor based on PB-mediated amplification together with signal enhancement of ordered CKM-3 for the quantification of MTMC.…”
Section: Applications Of Eccss Based On Cnm-modified Mipsmentioning
confidence: 99%
“…Em 1994 Karyakin e colaboradores demonstraram um eletrodo modificado com AP como uma ferramenta poderosa para a detecção de peróxido de hidrogênio em baixos valores de potencial. 44 Desde então, o AP e seus análogos vem sendo estudados como possíveis sensores para uma série de moléculas além do peróxido, como sulfito, 50 K + e Na + , 28 pesticidas, 51 colesterol, 52 BHT, 53 glicose, 54 rutina, 55…”
Section: Azul Da Prússia Como Alternativa Para Sensoresunclassified