2021
DOI: 10.1109/tmech.2020.3019431
|View full text |Cite
|
Sign up to set email alerts
|

A Monolithic Force Sensing Integrated Flexure Bonder Dedicated to Flip-Chip Active Soft-Landing Interconnection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 20 publications
(5 citation statements)
references
References 32 publications
0
2
0
Order By: Relevance
“…Additionally, the stroke, working frequency range, and the tracking accuracy of the proposed compliant mechanism are ≥100 µm, ≥30 Hz and ±2 µm, respectively [20,21]. The compliant mechanism has the advantages of high precision, low winding, and no friction, and can achieve ultra-high-precision and high-frequency motion within a small range [22][23][24]. Moreover, it has been demonstrated that it is effective for implementing mini-LED precision positioning by utilizing a 2-DOF-compliant mechanism [25][26][27].…”
Section: Introductionmentioning
confidence: 94%
“…Additionally, the stroke, working frequency range, and the tracking accuracy of the proposed compliant mechanism are ≥100 µm, ≥30 Hz and ±2 µm, respectively [20,21]. The compliant mechanism has the advantages of high precision, low winding, and no friction, and can achieve ultra-high-precision and high-frequency motion within a small range [22][23][24]. Moreover, it has been demonstrated that it is effective for implementing mini-LED precision positioning by utilizing a 2-DOF-compliant mechanism [25][26][27].…”
Section: Introductionmentioning
confidence: 94%
“…Notch-type pivots with lumped compliance are commonly used to provide bending and rotation movements, but they have some limitations. For example, they typically have high rotational stiffness, limited stroke length, and high concentrated stress [ 21 , 22 , 23 ]. These drawbacks restrict their application in high-precision positioning tasks.…”
Section: Design Principle Of Mechanismmentioning
confidence: 99%
“…To achieve rotational movement around the X -axis, a cross-axis flexural pivot can be used. This type of pivot has been extensively studied and modeled in previous research as cited in [ 11 , 22 , 24 ]. For this particular study, we selected this compliant module to provide rotational freedom around the X -axis.…”
Section: Design Principle Of Mechanismmentioning
confidence: 99%
“…due to the smaller the table height-todiameter ratio, the higher the advantages of equipment integration and stability, this paper designs the device height of only 75 mm. Considering the need for high precision and large stroke the SPAS is designed based on a compliant structure with a simple and compact configuration, no motion friction [30,31]. The stage employs piezoelectric ceramics as actuators.…”
Section: Introductionmentioning
confidence: 99%