2016
DOI: 10.1177/1932296816662884
|View full text |Cite
|
Sign up to set email alerts
|

A Multicenter Evaluation of the Performance and Usability of a Novel Glucose Monitoring System in Chinese Adults With Diabetes

Abstract: The system works well for people with diabetes in China, and it is easy to wear and use.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
53
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 54 publications
(56 citation statements)
references
References 18 publications
(22 reference statements)
3
53
0
Order By: Relevance
“…To our knowledge, no scientific studies have been published previously evaluating the feasibility of factory calibration besides the ones leading to FreeStyle Libre. [9][10][11][12][13] All calibration-related studies and publications were focused on understanding and improving the standard BG-based fingerstick calibration [14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30] or overcoming transient effects, such as lag and signal artifacts [31][32][33][34][35] that can impact calibration. This demonstrates the novelty of this alternative approach and also possibly the superiority of the chemistry used in FreeStyle Libre over other sensor systems.…”
Section: Implementation Of Factory Calibration For Freestyle Librementioning
confidence: 99%
“…To our knowledge, no scientific studies have been published previously evaluating the feasibility of factory calibration besides the ones leading to FreeStyle Libre. [9][10][11][12][13] All calibration-related studies and publications were focused on understanding and improving the standard BG-based fingerstick calibration [14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30] or overcoming transient effects, such as lag and signal artifacts [31][32][33][34][35] that can impact calibration. This demonstrates the novelty of this alternative approach and also possibly the superiority of the chemistry used in FreeStyle Libre over other sensor systems.…”
Section: Implementation Of Factory Calibration For Freestyle Librementioning
confidence: 99%
“…There is enough literature available highlighting the accuracy and safety of flash glucose monitoring personal use as a stand-alone system, just like CGMs. 4,[26][27][28][29][30][31] Future developments in flash glucose monitoring may include the availability of ''adjustable and predictable'' alerts and alarms and data made available on a mobile phone (so that patients do not need to carry another device). 32 Early versions of FreeStyle Libre link are available in Europe through an application on Android phones.…”
mentioning
confidence: 99%
“…As the FGM Libre system has only been available for a short time, the number of scientific papers assessing the quality and reliability of laboratory measurements, traditional glucometers or comparing FGM Libre with systems existing for a long time is not too large. However, several independent studies conducted in different patients (with type 1 diabetes and type 2 diabetes, in adults and children) confirmed that the measurements by scanning are reliable and are within the limits of permissible error (on the Clarke Error Grid) and MARD indexes amounted to a dozen or so percent, that is they remained at a similar level as in the case of CGM systems which have been available for years [8][9][10][11]. The accuracy of measurement is not affected by age, body mass index (BMI), the method of insulin administration or HbA 1 c [4,6].…”
Section: Discussionmentioning
confidence: 84%