2007
DOI: 10.1016/j.snb.2006.12.023
|View full text |Cite
|
Sign up to set email alerts
|

A multichannel electrochemical detector coupled with an ELISA microtiter plate for the immunoassay of 2,4-dichlorophenoxyacetic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0
1

Year Published

2007
2007
2019
2019

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(18 citation statements)
references
References 34 publications
(44 reference statements)
0
17
0
1
Order By: Relevance
“…The detection limit for free 2,4-D in water was 0.1 ng/mL. A similar immunosensor coupled with an ELISA microtiter plate was also reported (Deng and Yang, 2007), and the detection limit of 0.072 ng/mL was achieved. The advantages of the presented electrochemical detector were high stability and sample throughput, low detection limit, the ability to be repeatedly used, and no need for regeneration.…”
Section: Amperometric Methodsmentioning
confidence: 60%
“…The detection limit for free 2,4-D in water was 0.1 ng/mL. A similar immunosensor coupled with an ELISA microtiter plate was also reported (Deng and Yang, 2007), and the detection limit of 0.072 ng/mL was achieved. The advantages of the presented electrochemical detector were high stability and sample throughput, low detection limit, the ability to be repeatedly used, and no need for regeneration.…”
Section: Amperometric Methodsmentioning
confidence: 60%
“…During recent years new products based on the use of screen printed electrodes have made the use of such electrode material even more attractive. A disposable multichannel immunochemical sensor based on the array of eight working electrodes (gold) and a silver reference electrode printed on a ceramic substrate was, for example, recently developed [32,33]. A novel analytical immunosensor array, which combines the ease of use of the spectrophotometric microplate and the high sensitivity of the electrochemical transducer, has also recently been proposed.…”
Section: Electrochemical Immunosensorsmentioning
confidence: 99%
“…Deng et al [33] proposed an array immunosensor (MED) for simultaneous analysis of several water samples in order to monitor for 2,4-D contamination. A direct competitive immunoassay (Fig.…”
Section: Pesticides 2161 24-dichlorophenoxyacetic Acid 24-mentioning
confidence: 99%
“…With the emergence of nanostructured materials that enable nanoscale biomolecule confinement, a new class of ultrasensitive portable diagnostics tools has been developed for clinical health care applications. 1,2 However, identifying and matching new materials and technologies for a specific application have been the real challenge in designing and prototyping cost-effective, lab-on-a-chip-based diagnostics platforms. This research succeeds in demonstrating a potentially disruptive technology with the use of iridium oxide (IrOx) nanowires toward ''real-time'' point-of-care testing.…”
Section: Introductionmentioning
confidence: 99%