1981
DOI: 10.1016/0022-2364(81)90051-2
|View full text |Cite
|
Sign up to set email alerts
|

A multinuclear double-tuned probe for applications with solids or liquids utilizing lumped tuning elements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
41
0

Year Published

1992
1992
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(42 citation statements)
references
References 2 publications
1
41
0
Order By: Relevance
“…The scroll coil is incorporated into the circuit diagrammed in Figure 2, which is an updated version of the original Cross et al (15) circuit and is similar to those used in other applications (16)(17)(18)(19)(20)(21) The circuit is double-tuned to 500 MHz ( 1 H) and 202 MHz ( 31 P). Two variable capacitors (Polyflon NRP/VC10-12-06A, www.polyflon.com) are used in both the 1 H and 31 P tuning networks, indicated as C2 and C3 for the 1 H channel and C6 and C7 for the 31 P channel.…”
Section: Resultsmentioning
confidence: 99%
“…The scroll coil is incorporated into the circuit diagrammed in Figure 2, which is an updated version of the original Cross et al (15) circuit and is similar to those used in other applications (16)(17)(18)(19)(20)(21) The circuit is double-tuned to 500 MHz ( 1 H) and 202 MHz ( 31 P). Two variable capacitors (Polyflon NRP/VC10-12-06A, www.polyflon.com) are used in both the 1 H and 31 P tuning networks, indicated as C2 and C3 for the 1 H channel and C6 and C7 for the 31 P channel.…”
Section: Resultsmentioning
confidence: 99%
“…The L B , L C , C B , and C C were calculated in accordance with Eqs. [6], [7], [8], and [9]. As a result, the L B was 67 nH, and the L C was 83 nH.…”
Section: Methodsmentioning
confidence: 99%
“…19 F NMR experiments can possibly identify fluorine-containing compounds that are discriminable from the PVDF binder signal. [8][9][10] Correlations between the quantity of LiF on the cathode with respect to the number of cycles and the percentage of lithium loss from the cathode can be obtained.…”
mentioning
confidence: 99%
“…11 We designed, constructed, and tested an 7 Li and 19 F doubleresonance 600-MHz solid-state NMR probe with a solenoidal coil using a Cross-Waugh circuit. [12][13][14] Experimental Methods Probe Design and Probe Construction. The previously reported model for the design of a simple and effective probe was adapted, because the probe, which is the important interface between all NMR samples and the magnet fields resulting from RF pulses, has the strongest effects on the entire performance of the experiments.…”
mentioning
confidence: 99%
See 1 more Smart Citation