2005 IEEE International Conference on Industrial Technology
DOI: 10.1109/icit.2005.1600837
|View full text |Cite
|
Sign up to set email alerts
|

A Multiple-Input DC/DC Converter for Renewable Energy Systems

Abstract: This paper presents a multiple-input DC/DC converter for renewable energy systems. The proposed DC/DC converter can be used to obtain well-regulated output voltage from several power sources, such as wind turbines, photovoltaic arrays, fuel cells, etc. The energy provided by these power sources can be simultaneously transferred into the load. The proposed multiple-input DC/DC converter has the advantages of simple configuration, fewer components, lower cost and high efficiency. The operating principle, theoret… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(6 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…Timesharing method is used for the control, which can only allow one source to delivery power to load in one time interval. Also, the current ratings for these input circuits are higher with complicated interleaving control circuit [4]. Energy sources are more desired for simultaneous operation.…”
Section: School Of Electrical and Information Engineeringmentioning
confidence: 99%
“…Timesharing method is used for the control, which can only allow one source to delivery power to load in one time interval. Also, the current ratings for these input circuits are higher with complicated interleaving control circuit [4]. Energy sources are more desired for simultaneous operation.…”
Section: School Of Electrical and Information Engineeringmentioning
confidence: 99%
“…• Figure 2a shows the multi boost converter topology. The general model for this topology [2] is given by equation (1); where (α1) and (n) define respectively the duty cycle and parallel input converter number.…”
Section: Multi Boost and Multi Full Bridge Converters Modellingmentioning
confidence: 99%
“…The voltage drops in the L n and λ inductances are given by equation (2). The converter average model has a nonlinear behavior because of crosses between α1 control variable and V bus1 parameter.…”
Section: Multi Boost and Multi Full Bridge Converters Modellingmentioning
confidence: 99%
“…Even though two input sources with different voltages and different duty cycles can be achieved through the time share concept in [4], however it can only allow one source to delivery power to load within one time interval. Also, the current ratings for these input circuits are higher with complicated interleaving control circuit [5]. Compared with time share operation, simultaneous operation is more popular for multiple energy sources, in which case the energy sources can always deliver power to the load side at the same time.…”
Section: Introductionmentioning
confidence: 99%