2017
DOI: 10.1016/j.mechmat.2017.07.011
|View full text |Cite
|
Sign up to set email alerts
|

A multiscale model for damage progression and detection in piezo/pyroelectric composite laminates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…The matrix tensile strength is taken as 100 MPa and shear strength of 87.5 MPa. 32 The interface strength is taken as 31.72 MPa, and the ultimate interface shear strength is taken as 46.36 MPa. 33 The stress and strain distribution along the length of the tube are presented in Figures 6 and 7.…”
Section: Model Verificationmentioning
confidence: 99%
See 1 more Smart Citation
“…The matrix tensile strength is taken as 100 MPa and shear strength of 87.5 MPa. 32 The interface strength is taken as 31.72 MPa, and the ultimate interface shear strength is taken as 46.36 MPa. 33 The stress and strain distribution along the length of the tube are presented in Figures 6 and 7.…”
Section: Model Verificationmentioning
confidence: 99%
“…For each structure element that suffers any stage of damage, the final stress field can be extracted from ABAQUS to be implemented in the post processing stage. Back to the standalone laminate analysis, the fiber stresses can be obtained from equation ( 2) and the electrical displacement D 33 of the PZT fibers employed in all plies can be obtained using equation (32). At the end of the loading path, and for the selected locations in the plate structure shown in Figure 13, the electrical displacement D 33 for the electrically active fibers is obtained and compared with the undamaged values.…”
Section: Plate Problemmentioning
confidence: 99%
“…* Authors to whom any correspondence should be addressed. structural failure or long-term structural deterioration, maximizing the safety of such structures and their operation [7][8][9][10][11]. The selection of sensors is a critical part of the SHM system.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, piezoelectric sensors have simple structures, wide frequency-range of respond and fast responding speed. And they are rarely affected by temperature compared with other sensors, so piezoelectric sensors are widely used in SHM [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18]. Piezoelectric ceramic sensors are commonly used in SHM systems, such as lead zirconate titanate (PZT) ceramic sensor, which have the advantages of fast responding speed, good linearity and low price [4][5][6][7][12][13][14][15][16][17][18].…”
Section: Introductionmentioning
confidence: 99%