2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)
DOI: 10.1109/robot.2003.1241994
|View full text |Cite
|
Sign up to set email alerts
|

A new active microendoscope for exploring the sub-arachnoid space in the spinal cord

Abstract: This paper presents the design, development and preliminary test of a new active micmndoscope for neuroendoscopy and therapy of the spinal cord. Endoscopy of the spinal suh-arachnoid space is useful for some pathologies, hut it is a very challenging task for several reasons: the navigation space is very narrow, there are many blood vwels and delicate structures which could he damaged by manoeuvres and large forces and, finally, the Cerehro-Spinal Fluid (CSF) is a peculiar environment which must he preserved. A… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 11 publications
0
11
0
Order By: Relevance
“…The valves were regulated via On/Off signals due to their relatively slow commutation time (i.e., 20 ms). Finer control of capsule motion may be achieved via independent pulse width modulation (PWM) of the pressure at exhaust ports, as suggested in [26]. While this can be obtained by using faster and more expensive valves, we hypothesized that three different levels of pressure, combined with the field of view of the camera and the adjustment of tether length, were sufficient to inspect the surface of the stomach, while minimizing the overall cost of the platform.…”
Section: System Design and Fabricationmentioning
confidence: 99%
“…The valves were regulated via On/Off signals due to their relatively slow commutation time (i.e., 20 ms). Finer control of capsule motion may be achieved via independent pulse width modulation (PWM) of the pressure at exhaust ports, as suggested in [26]. While this can be obtained by using faster and more expensive valves, we hypothesized that three different levels of pressure, combined with the field of view of the camera and the adjustment of tether length, were sufficient to inspect the surface of the stomach, while minimizing the overall cost of the platform.…”
Section: System Design and Fabricationmentioning
confidence: 99%
“…Thus θ(s) can be approximated by a linear function given by θ(s) = π/2 + as; where, a = (θ L − π/2) /L (6) and (5) becomes…”
Section: Introductionmentioning
confidence: 99%
“…In [4] we described a new active micro-catheter for the exploration of the sub-arachnoid spinal space. The endoscope inside the catheter provides the surgeon with a direct vision of the spinal canal, but poses important safety issues.…”
Section: Introductionmentioning
confidence: 99%