2008
DOI: 10.1007/s10967-008-7312-6
|View full text |Cite
|
Sign up to set email alerts
|

A new approach for standard preparation in microbeam analysis: Development and validation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 6 publications
0
15
0
Order By: Relevance
“…were 20  40 (B-E) steps at 100 lm/step (beam size, 100 lm  100 lm), 60  60 (G and I) steps at 5 lm/step (beam size, 1 lm  1 lm) and 50  50 (J and K) steps at 1 lm/ step (beam size, 1 lm  1 lm). Uranium concentration range of image was calculated using thin standards for microbeam analysis developed at our laboratory [16]. sites in the epithelium (Fig.…”
Section: Elemental Imaging Of the Kidneymentioning
confidence: 99%
“…were 20  40 (B-E) steps at 100 lm/step (beam size, 100 lm  100 lm), 60  60 (G and I) steps at 5 lm/step (beam size, 1 lm  1 lm) and 50  50 (J and K) steps at 1 lm/ step (beam size, 1 lm  1 lm). Uranium concentration range of image was calculated using thin standards for microbeam analysis developed at our laboratory [16]. sites in the epithelium (Fig.…”
Section: Elemental Imaging Of the Kidneymentioning
confidence: 99%
“…We recently developed a thin-section standard using polyvinyl alcohol 11 and confirmed that the standard is adequate for quantitative analysis within a spatial resolution of around 10 × 10 µm 2 . 12,13 In the present study, we attempted to perform a quantitative local analysis of Sr in a micro-region of the scale with the standard.…”
Section: Introductionmentioning
confidence: 90%
“…11 Briefly, the standard solution of Sr (10000 ppm, SPEX Certi Prep, NJ, USA) was stirred into the optimal cutting temperature (OCT) compound (Sakura Finetechnical Co., Ltd., Tokyo, Japan) and deaerated. The final levels of Sr in the mixed solutions were 0-500 µg/g.…”
Section: Preparation Of Sr Standardsmentioning
confidence: 99%
“…The obtained elemental maps were colored from deep blue to red, and classified into 256 from the lower detection limit up to the maximum concentration in linear proportion to the element concentration. The uranium concentration range in the images was calculated using thin uranium standards for microbeam analysis (10 mm; 0-500 mg g À1 ) developed in our laboratory (Homma-Takeda et al, 2009a). The standards were analyzed under the same conditions as the samples.…”
Section: Msr-xrf Analysismentioning
confidence: 99%