A new approach of tap changer maintenance incorporating nanoparticle insulating oil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 28 publications
0
5
0
Order By: Relevance
“…The insulating oil with a low flash point might induce irreparable failures owing to flammable and combustible fumes created by overload or local overheating. 110,111 As a result, the flash point is the most critical of these three characteristics. When a little flame is close to the oil, the fire point is defined as the minimal temperature at which the oil vapour continues to burn for at least five seconds.…”
Section: Flash Point/fire Point/pour Pointmentioning
confidence: 99%
“…The insulating oil with a low flash point might induce irreparable failures owing to flammable and combustible fumes created by overload or local overheating. 110,111 As a result, the flash point is the most critical of these three characteristics. When a little flame is close to the oil, the fire point is defined as the minimal temperature at which the oil vapour continues to burn for at least five seconds.…”
Section: Flash Point/fire Point/pour Pointmentioning
confidence: 99%
“…Figure 2 shows a carbonized tap changer during maintenance of the OLTC. If the OLTC are not properly maintained or left unattended, the chances for it to explode is high as sparks during the tap changing process will ignite the highly flammable gas such as acetylene [3].…”
Section: Discharges Of High Energy (D2)mentioning
confidence: 99%
“…Figure 2 shows a carbonized tap changer during maintenance of the OLTC. If the OLTC are not properly maintained or left unattended, the chances for it to explode is high as sparks during the tap changing process will ignite the highly flammable gas such as acetylene [3]. Based on a DGA result by a condition-monitoring specialist, it is indicated that the OLTC was experiencing the thermal fault and discovered that the arm contacts and springs were severely burned in the red phase, as shown in Figure 3 Based on a DGA result by a condition-monitoring specialist, it is indicated that the OLTC was experiencing the thermal fault and discovered that the arm contacts and springs were severely burned in the red phase, as shown in Figure 3 [2].…”
Section: Partial Dischargementioning
confidence: 99%
See 1 more Smart Citation
“…Abdali et al showed that the insertion of 0.01% weight percentage of diamond nanoparticles inside mineral oil can reduce the hotspot temperature to 5.1 °C and enhance the coolant properties of the mineral oil [ 28 ]. Finally, Ghoneim et al introduced a new approach to transformer tap changer maintenance using insulating oil-based nanoparticles [ 29 ].…”
Section: Introductionmentioning
confidence: 99%