2015 IEEE Energy Conversion Congress and Exposition (ECCE) 2015
DOI: 10.1109/ecce.2015.7310532
|View full text |Cite
|
Sign up to set email alerts
|

A new DC-DC power converter derived from the TAB for bipolar DC microgrids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…The reason is, when V 1 in Equation ( 11) is multiplied with V 1 of Equation ( 8), there is no power transferred from port 1 to port 1 or it can also be represented as the phase angle between the same voltage V 1 is always zero. Hence, only the term containing V 2 can be seen in Equation (14). The second thing noticed from above equations is the values of equivalent leakage inductance.…”
Section: Calculation Of Equivalent Leakage Inductances In Delta Equiv...mentioning
confidence: 99%
See 1 more Smart Citation
“…The reason is, when V 1 in Equation ( 11) is multiplied with V 1 of Equation ( 8), there is no power transferred from port 1 to port 1 or it can also be represented as the phase angle between the same voltage V 1 is always zero. Hence, only the term containing V 2 can be seen in Equation (14). The second thing noticed from above equations is the values of equivalent leakage inductance.…”
Section: Calculation Of Equivalent Leakage Inductances In Delta Equiv...mentioning
confidence: 99%
“…13 However, DAB's single-input single-output (SISO) topology is insufficient for more complicated systems, such as the isolated multibattery charging systems mentioned earlier. 14 Connecting PV, grid, battery, or standalone PV, battery, and supercapacitor/fuel cell systems would require multiple DAB converters, which can increase the complexity of the system. 15 Additionally, controlling power flow in such a system becomes challenging, as good communication between all the converters is necessary to ensure proper operation.…”
Section: Introductionmentioning
confidence: 99%
“…The system flexibility gets enhanced by the introduction of various PECs, as voltage regulation and control become much easier [54], [55]. Based on this, various configurations such as transformer-enabled DC networks [56] - [58], bipolar networks [59], [60], and DC grids with redundant bus structures [61], have been proposed. The classification of DC microgrid architectures is portrayed in Fig.…”
Section: DC Microgrid Architecturesmentioning
confidence: 99%
“…The phase-shift angle is obtained by comparing the measured DC voltage with a reference signal, thus generating an error applied to a proportional-integral (PI) controller. The controller output signal is converted into an angle by means of the gyrator based on [28] and [29].…”
Section: Control Systemmentioning
confidence: 99%