1995
DOI: 10.4055/jkoa.1995.30.5.1433
|View full text |Cite
|
Sign up to set email alerts
|

A New Design of Miniplate Staple for High Tibial Osteotomy: Biomechanical Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
7
0

Year Published

2001
2001
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 0 publications
1
7
0
Order By: Relevance
“…16,30,31 The aetiology of the decrease of inclination has been attributed to anterior collapse resulting from the difference in the subchondral bone 32,33 and the reduced strength of the osteotomised fragments. 34,35 The incidence of patella infera after osteotomy has been reported as 10% to 30%. 30,31 The postoperative decrease in the inclination of the tibial plateau has been reported as approximately 3° to 10°.…”
Section: Discussionsupporting
confidence: 89%
“…16,30,31 The aetiology of the decrease of inclination has been attributed to anterior collapse resulting from the difference in the subchondral bone 32,33 and the reduced strength of the osteotomised fragments. 34,35 The incidence of patella infera after osteotomy has been reported as 10% to 30%. 30,31 The postoperative decrease in the inclination of the tibial plateau has been reported as approximately 3° to 10°.…”
Section: Discussionsupporting
confidence: 89%
“…3). 4,5 The final alignment was confirmed on the computer screen ( Fig. 4) using the image intensifier.…”
Section: Methodsmentioning
confidence: 99%
“…3 Advantages of the lateral closed-wedge osteotomy include the presence of broad metaphyseal opposing surfaces, offering quicker healing 1 and negating the risk of loss of correction, fixation failure, delayed union and nonunion and satisfactory long-term results have been reported. [4][5][6][7][8] However, there are potential risks of neurovascular injury and of creating additional difficulty when converting a knee with a previous osteotomy to a total knee replacement (TKR). 9,10 Several long-term studies indicate that accurate correction has been the leading predictor for success.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…1.1 (BrainLAB, Heimstetten, Germany) was used for medial compartment osteoarthritis with a varus deformity >10°. A miniplate staple (U&I Co., Uijeongbu, Korea) was used as a fixative 15) . Informed consent was obtained from all patients, none of whom declined to participate.…”
Section: Methodsmentioning
confidence: 99%