A new directional relay based on the measurement of fault generated current transients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1998
1998
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…So we adopt over current protection as the main protection of the distribution network. due to the principle of substation integrated protection,integrated protection is applied to different regions of distribution network according to system buses and power supplies [11]. Thus the integrated protection is applied to regions of microgrid.…”
Section: Figure2a Centralized Integrated Protection System Based On C...mentioning
confidence: 99%
“…So we adopt over current protection as the main protection of the distribution network. due to the principle of substation integrated protection,integrated protection is applied to different regions of distribution network according to system buses and power supplies [11]. Thus the integrated protection is applied to regions of microgrid.…”
Section: Figure2a Centralized Integrated Protection System Based On C...mentioning
confidence: 99%
“…Sanderson and his associates [62,63] worked on fast unit protection of multiterminal lines and presented a method based on directional comparison, which is based on the evaluation of the current direction at the terminal with the largest voltage change. Bo and his coworkers [64,65] presented a new directional comparison technique that compares the polarity of fault-generated transient current signals in the system with a two terminal transmission line.…”
Section: Directional Comparison Based Algorithmmentioning
confidence: 99%
“…The traveling wave based protection possesses the fastest operation, but when the faults happen at a voltage inception angle close to the zero, they could not generate the significant traveling wave, and the traveling wave measurement is also affected by the bandwidth limitation of the transducers. The principles based on the fault generated high frequency transient components have been proposed in [4][5][6][7]. The direction comparison based on transient current signals is directly comparing the polarity of the transient current, which does not require the voltage signal to decide the direction.…”
Section: Introductionmentioning
confidence: 99%