“…When the belt was empty or if there was not enough pulverized coal to be analyzed, distance values were about 95 mm, so the XRF analyzer was interrupted (off). After pulverized coal was smoothed by the sled, the distance values were almost entirely in the range of 81.1-81.6 mm due to the machinery vibration of conveyor belt and rough surface textures of pulverized coal, then the XRF analyzer would continuously measure online for 100 s. In the previous study, Ge et al 25 found that the accuracy of measurement can be accepted when the distance changed within 0.5 mm; the intensity-distance correction method 15 was used hardly at all.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…When the belt was empty or if there was not enough pulverized coal to be analyzed, distance values were about 95 mm, so the XRF analyzer was interrupted (off). After pulverized coal was smoothed by the sled, the distance values were almost entirely in the range of 81.1-81.6 mm due to the machinery vibration of conveyor belt and rough surface textures of pulverized coal, then the XRF analyzer would continuously measure online for 100 s. In the previous study, Ge et al 25 found that the accuracy of measurement can be accepted when the distance changed within 0.5 mm; the intensity-distance correction method 15 was used hardly at all.…”
Section: Resultsmentioning
confidence: 99%
“…After pulverized coal was smoothed by the sled, the distance values were almost entirely in the range of 81.1–81.6 mm due to the machinery vibration of conveyor belt and rough surface textures of pulverized coal, then the XRF analyzer would continuously measure online for 100 s. In the previous study, Ge et al. 25 found that the accuracy of measurement can be accepted when the distance changed within 0.5 mm; the intensity–distance correction method 15 was used hardly at all.
Figure 4.Typical measuring distance results by laser rangefinder.
…”
Section: Resultsmentioning
confidence: 99%