2007
DOI: 10.1109/nssmic.2007.4436424
|View full text |Cite
|
Sign up to set email alerts
|

A new four channel pulse shape discriminator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 1 publication
0
8
0
Order By: Relevance
“…The neutron detectors were mounted side by side 17.5 cm from the center of the LEU cube as shown in Figure . The liquid scintillator signal has two light decay time constants that can be used to discriminate signals due to gammas (fast) and neutrons (slow). The Mesytec NIM module MPD-4 was used to discriminate between gammas and neutron signals using Pulse Shape Discrimination (PSD) techniques, as described in [28]. In particular, the module was calibrated using fission neutrons from a 252 Cf source and gammas from a 137 Cs source and its neutron-trigger output was fed to a dedicated input on the MMT digitizing boards.…”
Section: Methodsmentioning
confidence: 99%
“…The neutron detectors were mounted side by side 17.5 cm from the center of the LEU cube as shown in Figure . The liquid scintillator signal has two light decay time constants that can be used to discriminate signals due to gammas (fast) and neutrons (slow). The Mesytec NIM module MPD-4 was used to discriminate between gammas and neutron signals using Pulse Shape Discrimination (PSD) techniques, as described in [28]. In particular, the module was calibrated using fission neutrons from a 252 Cf source and gammas from a 137 Cs source and its neutron-trigger output was fed to a dedicated input on the MMT digitizing boards.…”
Section: Methodsmentioning
confidence: 99%
“…The neutron detector consisted of a p-terphenyl crystal [2], 8 cm in diameter and 5 cm thick, coupled by a quartz window and optical interface to a 76 mm Photonis XP4312 photomultiplier tube. The negative anode signal was split in two, with the larger part supplied to the Mesytec MPD-4 module [3] which provided the pulse shape (PS) signal into the amplitude-to-digital converter (ADC) and the start signal for the time-to-amplitude converter (TAC). The smaller part of the signal (1/200) was fed into a charge sensitive preamplifier (QPA), amplified with a shaping time of 1µs and the bipolar output was connected to the ADC for pulse height (PH) measurements.…”
Section: Methodsmentioning
confidence: 99%
“…[6]. This target was placed at the center of the liquid scintillator (BC-501A) The pulses from the detectors were processed using analog electronics built around Mesytec MPD-4 modules [12]. CAEN Analog to Digital Converters (ADCs) and Time to Digital Converters (TDCs) were used to digitize and store the outputs of the MPD-4 modules for offline analysis.…”
Section: Experimental Descriptionmentioning
confidence: 99%