IADC/SPE Drilling Conference and Exhibition 2016
DOI: 10.2118/178792-ms
|View full text |Cite
|
Sign up to set email alerts
|

A New Friction Reduction Tool with Axial Oscillation Increases Drilling Performance: Field-Testing with Multiple Vibration Sensors in One Drill String

Abstract: Weight transfer problems, hanging-up, poor toolface control and diminishing ROP are all problems that are encountered with steerable motors in high angle and horizontal wells. A number of oscillation devices have been introduced to the market over the years to aid these common problems. Both axial and lateral vibration tools have proven to provide improvements to drilling performance and toolface control. However, as with any device, there are always limiting factors, and oscillation devices cou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(1 citation statement)
references
References 2 publications
0
1
0
Order By: Relevance
“…Both VOTs and LATs could have negative impact on reliability of electronic and mud pulse equipment results in nonproductive time tripping for failed equipment due to the fact that oscillations and vibrations are being introduced to the BHA and drill string. A new axial FRT was developed by Jones et al [60], and the high-frequency burst data showed that no excessive shock and vibration were being induced into the BHA and string from the FRT, presented that the FRT was effective in transmitting axial oscillations along the BHA without introducing any damaging effects to the BHA.…”
Section: New Understandings Of Drillstring Dynamic Behaviorsmentioning
confidence: 99%
“…Both VOTs and LATs could have negative impact on reliability of electronic and mud pulse equipment results in nonproductive time tripping for failed equipment due to the fact that oscillations and vibrations are being introduced to the BHA and drill string. A new axial FRT was developed by Jones et al [60], and the high-frequency burst data showed that no excessive shock and vibration were being induced into the BHA and string from the FRT, presented that the FRT was effective in transmitting axial oscillations along the BHA without introducing any damaging effects to the BHA.…”
Section: New Understandings Of Drillstring Dynamic Behaviorsmentioning
confidence: 99%