“…Therefore, the traditional magnetic field calculation method is no longer suitable for HTS machines. At present, the general methods for calculating motor field include the finite element method (FEM) [13,14,15], conformal transformation method [16,17,18,19], equivalent magnetic circuit method [20,21,22,23], and subdomain analytical method [24,25,26,27]. In this paper, we present an accurate sub-domain analytical model for calculating the magnetic field of a synchronous generator with high-temperature superconducting (HTS) excitation and armature windings that have a non-magnetic fixture.…”