2002
DOI: 10.1109/tpwrd.2002.804015
|View full text |Cite
|
Sign up to set email alerts
|

A new method for real-time monitoring of high-voltage transmission-line conductor sag

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(18 citation statements)
references
References 8 publications
0
18
0
Order By: Relevance
“…Currently, devices are increasingly used to estimate RTLR. For example, several devices to monitor conductor ampacity have been developed [5], [6], along with systems to estimate RTLR over large network areas using weather data. In order to fully exploit the advantages provided by DLR, circuit ampacity forecasts are often required, as most grid operation decisions are taken at least one day ahead.…”
Section: Fig 1 Evolution Of Static Line Rating and Real Line Ratingmentioning
confidence: 99%
See 1 more Smart Citation
“…Currently, devices are increasingly used to estimate RTLR. For example, several devices to monitor conductor ampacity have been developed [5], [6], along with systems to estimate RTLR over large network areas using weather data. In order to fully exploit the advantages provided by DLR, circuit ampacity forecasts are often required, as most grid operation decisions are taken at least one day ahead.…”
Section: Fig 1 Evolution Of Static Line Rating and Real Line Ratingmentioning
confidence: 99%
“…Values of the forecast variable Y are calculated for each quantile  a function ̂ as shown in (5). Then the function ̂ is set as a linear function of the input , with its parameters defined to minimize (4) and can be calculated as in (6) where and .…”
Section: Quantile Linear Regression Model (Qlr)mentioning
confidence: 99%
“…The other model, without measuring the wind speed, is also established based on the conductor sag (i.e., Temperature-Sag model) [28,29]. Instead of measuring directly by sensors, the conductor temperature is calculated by the sag-temperature behavior [30].…”
Section: Introductionmentioning
confidence: 99%
“…There are systems based on measuring the sag or tension of the conductor or weather-related magnitudes assuming that the right parameters of the lines are known, see e.g. Albizu et al (2013), Olsen and Edwards (2002) and the references therein. On the contrary, the approach proposed in this paper will determine the state of the line from the synchronized voltage and current phasor measurements measured by the phasor measurement units (PMU) from the both ends of the line and ambient weather conditions.…”
Section: Introductionmentioning
confidence: 99%