Abstract:A physically and statistically based method for steam generator (SG) heat exchanger tubes (HET) integrity assessment is proposed. The method based is on the stochastic laws of crack dimensions distribution with taking into account its growth, limit load-model of cracked tube, and SG plugging statistics. Based on the history of the tubes, plugging of the specific SG three statistical parameters has to be found: initial number of defects, stochastic parameter of defect depth, and the defect growth rate. The deve… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.