A new power line conditioner for harmonic compensation in power systems

Abstract: -This paper proposes a new power line conditioner consisting of two sinall rating series active filters and a shunt passive filter. The power line conditioner4ms at a general filtering system which will be installed at the point of common coupling in a power system feeding harmonic-sensitive loads and unidentified harmonicproducing loads. One of the two active filters is connected in series with the supply, while another is in series with the shunt passive filter. The purpose of the power line conditioner is t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
56
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 171 publications
(56 citation statements)
references
References 8 publications
0
56
0
Order By: Relevance
“…Thus, the proposed FC has better dynamic behavior than conventional PI control. It is claimed [6][7][8] that the fuzzy logic control yields the results, which are superior to those, obtained with the conventional controllers. In the FC, the simplicity of a PI controller is combined with the intelligence and adaptiveness of the fuzzy logic based control system.…”
Section: A Fuzzy Controllermentioning
confidence: 87%
See 1 more Smart Citation
“…Thus, the proposed FC has better dynamic behavior than conventional PI control. It is claimed [6][7][8] that the fuzzy logic control yields the results, which are superior to those, obtained with the conventional controllers. In the FC, the simplicity of a PI controller is combined with the intelligence and adaptiveness of the fuzzy logic based control system.…”
Section: A Fuzzy Controllermentioning
confidence: 87%
“…The tracking of the system on the sliding surface is governed by satisfying the natural control law, 0 ≤ s s (6) The equivalent control can be calculated from s . The expression, s for the active filter is obtained by ( )…”
Section: The Inverter Modelmentioning
confidence: 99%
“…Later, they were developed to compensate wider targets like the reactive and unbalance components, receiving then the denomination of Active Power Line Conditioner, APLC [1]. Although, the emphasis must be focused in the Unified Power Quality Conditioners, UPQC [2][3][4][5][6][7][8], which integrate in one module a combination of series and parallel APFs. Both converters are necessary because of the exposed reasons in the last paragraph, for a complete and generic load conditioning.…”
Section: Introductionmentioning
confidence: 99%
“…Nowadays, PWM rectifiers have been widely applied in series of industrial fields, such as Static Reactive Power Generator (SVG), Active Power Filter (APF), Unified Power Flow Controller (UPFC), High Voltage DC Transmission (HVDC) and some renewable energy generation system [1][2][3][4][5][6]. The key issues concerning the control of a threelevel voltage source PWM rectifier are about neutral potential balancing, switch losses and the cross-coupling between i d and i q .…”
Section: Introductionmentioning