1993
DOI: 10.1016/0017-9310(93)90089-o
|View full text |Cite
|
Sign up to set email alerts
|

A new pressure drop correlation for subcooled flow boiling of refrigerants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

1996
1996
2023
2023

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 2 publications
0
3
0
1
Order By: Relevance
“…Therefore, the flow mechanism of SP pressure drop cannot be simply applied to the hypervapotron. Subcooled boiling flow has also been studied in depth, and many pressure drop correlations have been proposed [26,[30][31][32][33]. The forms of subcooled boiling pressure drop correlations are different, but most of them contain r.…”
Section: Authors Correlationsmentioning
confidence: 99%
“…Therefore, the flow mechanism of SP pressure drop cannot be simply applied to the hypervapotron. Subcooled boiling flow has also been studied in depth, and many pressure drop correlations have been proposed [26,[30][31][32][33]. The forms of subcooled boiling pressure drop correlations are different, but most of them contain r.…”
Section: Authors Correlationsmentioning
confidence: 99%
“…This represents the effects of heat flux, inlet subcooling, and channel length, respectively, as shown in equations (3)-( 6)). Because it is difficult to directly measure the void fraction through a visualization experiment under sub-cooled flow boiling experimental conditions, The twophase pressure drop correlations presented in previous studies [9][10][11][12][13][14] were developed by expressing the correlation as a function of variables that can affect the amount of vapor present in the channel. The prediction performance of the existing correlations through equation (7) are shown in figure 7 and table 2.…”
Section: Newly Developed Correlation With Ai Regressionmentioning
confidence: 99%
“…Tong [12] ( ) ( ) ( ) In summary, many experimental studies have been conducted on the two-phase pressure drop multiplier under subcooled flow boiling conditions, but most of them are concentrated in the microchannel, as shown in table 3. In addition, there are a few experimental studies on macro-channels such as Hahne [11] and Baburajan [13], but the maximum heat flux in their research does not exceed 500 kW m −2 . Therefore, in this study, the authors intend to develop a two-phase pressure drop correlation for a swirl tube under one-side high heat load conditions.…”
Section: Newly Developed Correlation With Ai Regressionmentioning
confidence: 99%
“…Em se realizando a correlação com os resultados experimentais, a relação que define o multiplicador bifásico, conforme HAHNE et aL (1993) (3.5) apresenta que tal parâmetro é a relação entre a perda de carga bifásica e a monofásica. Caso seja avaliada a perda de carga monofásica para o líquido, o multiplicador bifásico seria apresentado como tftl 2 e, no caso do vapor, rj;./.…”
Section: Visualização Do Escoamentounclassified