A new purification method based on a thiol silica column for high precision antimony isotope measurements

Abstract: In this study, a new purification procedure for high precision Sb isotopic analysis was developed by using a thiol silica gel column and applied to determine Sb isotope composition in...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(22 citation statements)
references
References 25 publications
0
22
0
Order By: Relevance
“…A 55 single-step procedure using thiol-functionalized material 56 (cotton fibres or cellulose powder) was sufficient for the 57 purification of water samples even at low Sb concentration 58 (river water, groundwater) 13,15,16 or for solid samples highly 59 concentrated with Sb (stibnite) 16 . However, we faced major 60 drawbacks using these materials such as extended processing 17 proposed a new single-step purification method based 4 on thiol-functionalized silica. Antimony was successfully 5 purified (Sb recovery of 95.2%) from water samples 6 contaminated by the Xikuangshan antimony mine (China) that presented extremely high Sb concentrations (up to 30 mg L -1 ).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…A 55 single-step procedure using thiol-functionalized material 56 (cotton fibres or cellulose powder) was sufficient for the 57 purification of water samples even at low Sb concentration 58 (river water, groundwater) 13,15,16 or for solid samples highly 59 concentrated with Sb (stibnite) 16 . However, we faced major 60 drawbacks using these materials such as extended processing 17 proposed a new single-step purification method based 4 on thiol-functionalized silica. Antimony was successfully 5 purified (Sb recovery of 95.2%) from water samples 6 contaminated by the Xikuangshan antimony mine (China) that presented extremely high Sb concentrations (up to 30 mg L -1 ).…”
Section: Introductionmentioning
confidence: 99%
“…11 Depending on the Sb concentration in purified samples, 12 different sample introduction techniques have been applied for 13 MC-ICP-MS analysis (Table 1). For high Sb concentration (> 50 14 µg L -1 ), wet plasma conditions [14][15][16] or a desolvation system 17 1). In addition, even though the purification 21 step remains essential to remove hydride forming elements 22 (e.g.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…stibnite) was favoured because it was thought most likely to detect micrometre-scale processes reflected in the Sb isotopes. A new purification technique for Sb isotopes was designed by Li et al 180 They pre-reduced the sample using KI and ascorbic acid before a thiol silica column, eluted with HCl, was used to separate Sb from matrix elements. The approach did not appear to cause any isotope fractionation.…”
Section: Isotope Analysismentioning
confidence: 99%
“…Then, the purified antimony isotope was injected into plasma through hydride generation (HG), which can increase the analyte sensitivity. Since then, many other researchers have been developing and improving the antimony isotope analytical methods (Table S2), although these methods are often only applicable to specific sample types (e.g., glass and drainage water) with a recovery rate varying from 76 to 104%.…”
Section: Introductionmentioning
confidence: 99%