2013
DOI: 10.1016/j.fusengdes.2013.02.053
|View full text |Cite
|
Sign up to set email alerts
|

A new radiation-hard endoscope for divertor spectroscopy on JET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Additionally, systems like KL11, shown in figure 8, include options for the in situ calibration of the endoscope transmittance during the experimental campaign, which allow the continuous tracking of possible degradation with time. The measured transmittance of the entire endoscope system for wavelengths λ > 500 nm does not show any detectable altering of the transmittance [26,27]. For λ < 500 nm we observe some degradation (≈40% at 400 nm).…”
Section: Examples Of the Divertor View And Wide Angle Viewing System ...mentioning
confidence: 72%
See 3 more Smart Citations
“…Additionally, systems like KL11, shown in figure 8, include options for the in situ calibration of the endoscope transmittance during the experimental campaign, which allow the continuous tracking of possible degradation with time. The measured transmittance of the entire endoscope system for wavelengths λ > 500 nm does not show any detectable altering of the transmittance [26,27]. For λ < 500 nm we observe some degradation (≈40% at 400 nm).…”
Section: Examples Of the Divertor View And Wide Angle Viewing System ...mentioning
confidence: 72%
“…A new endoscope [26,27] with an improved spatial resolution and thus delivering images of high quality, gives a unique opportunity for monitoring the surface temperature of the divertor tiles in the NIR spectral range. The endoscope covers the spectral range from 390 nm to 2500 nm with a high optical transmittance (⩾60% in the NIR wavelength range) as well as a high spatial resolution, that is less than 2 mm at the object plane.…”
Section: Examples Of the Divertor View And Wide Angle Viewing System ...mentioning
confidence: 99%
See 2 more Smart Citations
“…The recycling flux close to the divertor target plates was measured by Langmuir probes as well as spectroscopically by deuterium Balmer-α and molecular emission of the Fulcher band [15]. A spectroscopic camera was used to discriminate the D α and WI emission on the HFS top and bottom divertor during the ELM and in the inter-ELM period [29].…”
Section: Resultsmentioning
confidence: 99%