2010 IEEE Energy Conversion Congress and Exposition 2010
DOI: 10.1109/ecce.2010.5618257
|View full text |Cite
|
Sign up to set email alerts
|

A new resonant active clamping technique for bi-directional converters in HEVs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…For the lowered power delivery, the efficiency of the original solution was higher, but on the other hand, it must be stated here that the switching frequency was 5 times lower. In principle, presented experimental measurements declare that with the use of optimized inductive components, it is possible to improve efficiency together with power density as well [20][21][22].…”
Section: Performance Evaluation For High-frequency Operation Using In...mentioning
confidence: 88%
See 1 more Smart Citation
“…For the lowered power delivery, the efficiency of the original solution was higher, but on the other hand, it must be stated here that the switching frequency was 5 times lower. In principle, presented experimental measurements declare that with the use of optimized inductive components, it is possible to improve efficiency together with power density as well [20][21][22].…”
Section: Performance Evaluation For High-frequency Operation Using In...mentioning
confidence: 88%
“…For the lowered power delivery, the efficiency of the original solution was higher, but on the other hand, it must be stated here that the switching frequency was 5 times lower. In principle, presented experimental measurements declare that with the use of optimized inductive components, it is possible to improve efficiency together with power density as well [20][21][22] When analyzing the efficiency results of an optimized coil converter made with an unevenly distributed shortened air gap, it is clear that the efficiency of the PFC converter with these coils was lower than expected, which probably resulted in increased lossesincrease in core volume but also due to increased current ripple [3,20]. This could be due to the effect of the aluminum heatsink, which was close to the coils (Figure 16), reducing their inductance.…”
Section: Performance Evaluation For High-frequency Operation Using In...mentioning
confidence: 90%
“…Regarding current ripples, they influence the effective value of current of the output capacitor, what affects its lifetime. Therefore, analyses according to current ripples must be provided if the optimized operation of the converter is the target [22][23][24].…”
Section: Bi-bb Converter From Non-modular To Modular Topology-propert...mentioning