2014
DOI: 10.1016/j.snb.2013.12.037
|View full text |Cite
|
Sign up to set email alerts
|

A new rhodamine derivative-based chemosensor for highly selective and sensitive determination of Cu2+

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
30
1

Year Published

2014
2014
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 80 publications
(32 citation statements)
references
References 38 publications
1
30
1
Order By: Relevance
“…The obtained K a strongly supported RECM-Cu 2+ 1:1 binding stoichiometry and showed a strong probe in comparison with some recently-reported work on Cu 2+ fluorescent and colorimetric probes [5,16,46]. Most of the various Cu 2+ -rhodamine-based chemosensors have already been developed and involve a coordination mode with 1:1 stoichiometry, which is the most possible binding mode of rhodamine-based chemosensors and Cu 2+ [5,24,25,32]. However, there are few types of research demonstrating different molar ratios for newly-developed rhodamine-based derivatives and Cu 2+ .…”
Section: Structure and Complexation Mechanismsupporting
confidence: 78%
See 3 more Smart Citations
“…The obtained K a strongly supported RECM-Cu 2+ 1:1 binding stoichiometry and showed a strong probe in comparison with some recently-reported work on Cu 2+ fluorescent and colorimetric probes [5,16,46]. Most of the various Cu 2+ -rhodamine-based chemosensors have already been developed and involve a coordination mode with 1:1 stoichiometry, which is the most possible binding mode of rhodamine-based chemosensors and Cu 2+ [5,24,25,32]. However, there are few types of research demonstrating different molar ratios for newly-developed rhodamine-based derivatives and Cu 2+ .…”
Section: Structure and Complexation Mechanismsupporting
confidence: 78%
“…The first idea to consider RECM as a Cu 2+ sensitive and selective fluorescent and colorimetric chemosensor was based on the spirocycle opening mechanism, which was the same as reported spirocycle rhodamine-based derivatives [5,10,16,24,25,36]. With this consideration, directly linked chelating agents to rhodamine spirolactam moiety including one methylamide N and two carbonyl O atoms made a possible binding pocket of RECM toward Cu 2+ and induced the spirolactam ring opening upon RECM and Cu 2+ binding interaction.…”
Section: Structure and Complexation Mechanismmentioning
confidence: 99%
See 2 more Smart Citations
“…Moreover, they require pretreatment procedures, and use costly instruments. Among various strategies, optical methods based on colorimetric and fluorescent probes have attracted much attention due to their simplicity, high selectivity and sensitivity, low cost, and real-time monitoring [13], [14]. As the fluorometric method can reach a very low detection limit, considerable affords have been devoted to develop fluorescent probe for mercapto biomolecules in recent years [15]- [20].…”
Section: Introductionmentioning
confidence: 99%