2012
DOI: 10.1088/0957-0233/23/9/094004
|View full text |Cite
|
Sign up to set email alerts
|

A new Ultra Precision Interferometer for absolute length measurements down to cryogenic temperatures

Abstract: A new Ultra Precision Interferometer (UPI) was built at Physikalisch-Technische Bundesanstalt. As its precursor, the precision interferometer, it was designed for highly precise absolute length measurements of prismatic bodies, e.g. gauge blocks, under well-defined temperature conditions and pressure, making use of phase stepping imaging interferometry. The UPI enables a number of enhanced features, e.g. it is designed for a much better lateral resolution and better temperature stability. In addition to the or… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(22 citation statements)
references
References 21 publications
0
22
0
Order By: Relevance
“…Multi-wavelength phase-shifting interferometry was used to measure strain maps of the complete sample surface with high accuracy using the PTB (Physikalisch-Technische Bundesanstalt) ultraprecision interferometer (UPI) [54] with a sample environment which allows one to heat the sample (up to 200 °C) and to apply an electric field ( Figure 15). Absolute length change measurements were evaluated at room temperature and 100 °C using a commercial PZT sample.…”
Section: Full-field Multi-wavelength Phase-shifting Interferometrymentioning
confidence: 99%
“…Multi-wavelength phase-shifting interferometry was used to measure strain maps of the complete sample surface with high accuracy using the PTB (Physikalisch-Technische Bundesanstalt) ultraprecision interferometer (UPI) [54] with a sample environment which allows one to heat the sample (up to 200 °C) and to apply an electric field ( Figure 15). Absolute length change measurements were evaluated at room temperature and 100 °C using a commercial PZT sample.…”
Section: Full-field Multi-wavelength Phase-shifting Interferometrymentioning
confidence: 99%
“…Thermal expansion of ultra stable materials at cryogenic temperatures is of increasing scientific interest driven by technological applications [2][3][4][5][6][7] . High accuracy CTE values at cryogenic temperatures are essential e.g.…”
Section: Introductionmentioning
confidence: 99%
“…Alternatively, thermal expansion coefficient was measured in Physikalisch-Technische Bundesanstalt (PTB) with PTB's Ultra Precision Interferometer (UPI) described in [25]. For this, sample 2 with the same dimensions and specifications but a slightly better parallelism was used.…”
Section: Methodsmentioning
confidence: 99%