2017
DOI: 10.15171/jhp.2018.08
|View full text |Cite
|
Sign up to set email alerts
|

A new validated high-performance liquid chromatography method for standardization of rosmarinic acid in Salvia extracts

Abstract: In the present study, a new validated HPLC method was developed which is suitable for analysis of rosmarinic acid and standardization of Labiateae family plants like Salvia, Melissa, Origanum, Lavandula, Rosmarinus, Thymus, Zataria, Mentha, Perovskia, Zhumeria, and Satureja species. Please cite this paper as: Ghanadian M Introduction:Tea bags or infuses of Salvia species from Lamiaceae family are traditionally used for the treatment of cough, and throat inflammations. They are known for antioxidant proper… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…81 The temperature of the columns is usually 25°C to 30°C during the measurement of RA, 16,58,82,83 but higher temperatures also have been reported. 23,84,85 Ziaková and Brandšteterová 59 chose several RP columns for separation of RA from various Lamiaceae plants. They tested the following analytical columns: GROM-SIL 100 ODS-0 AB, 120 ODS-3 CP, 120 ODS-4 HE, SEPARON SGX C18, Symmetry Shield C18, Symmetry C18, Develosil ODS), C8 (GROM-SIL 100 OCTYL-4 FE), and CN (GROM-SIL 120 CYAN-3CP).…”
Section: High-performance Liquid Chromatography Columnsmentioning
confidence: 99%
See 1 more Smart Citation
“…81 The temperature of the columns is usually 25°C to 30°C during the measurement of RA, 16,58,82,83 but higher temperatures also have been reported. 23,84,85 Ziaková and Brandšteterová 59 chose several RP columns for separation of RA from various Lamiaceae plants. They tested the following analytical columns: GROM-SIL 100 ODS-0 AB, 120 ODS-3 CP, 120 ODS-4 HE, SEPARON SGX C18, Symmetry Shield C18, Symmetry C18, Develosil ODS), C8 (GROM-SIL 100 OCTYL-4 FE), and CN (GROM-SIL 120 CYAN-3CP).…”
Section: High-performance Liquid Chromatography Columnsmentioning
confidence: 99%
“…The temperature of the columns is usually 25°C to 30°C during the measurement of RA, 16,58,82,83 but higher temperatures also have been reported. 23,84,85…”
Section: High-performance Liquid Chromatography Columnsmentioning
confidence: 99%