1991
DOI: 10.1016/0960-1686(91)90233-w
|View full text |Cite
|
Sign up to set email alerts
|

A new wind tunnel technique for investigating gas diffusion behind a structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

1994
1994
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 2 publications
0
10
0
Order By: Relevance
“…The rotational speed is controlled by a pulse motor so that the disturbance of airflow by the rotation of a topographical model can be avoided. Okabayashi et al 41 compared the result of the wind tunnel experiment with data from a field tracer experiment for a 1/10-scale model of a ventilation tower and confirmed the reliability of the overlapping method.…”
Section: Evaluation Of Topographical Effectsmentioning
confidence: 92%
See 1 more Smart Citation
“…The rotational speed is controlled by a pulse motor so that the disturbance of airflow by the rotation of a topographical model can be avoided. Okabayashi et al 41 compared the result of the wind tunnel experiment with data from a field tracer experiment for a 1/10-scale model of a ventilation tower and confirmed the reliability of the overlapping method.…”
Section: Evaluation Of Topographical Effectsmentioning
confidence: 92%
“…The overlapping technique and the schematic of the wind tunnel used in this study are described in detail by Okabayashi et al 41 The wind tunnel experiment using the overlapping technique was conducted by the Nagasaki Research and Development Center for Mitsubishi Heavy Industries. The wind tunnel has a test section 3 m wide, 2 m high, and 25 m long.…”
Section: Evaluation Of Topographical Effectsmentioning
confidence: 99%
“…The present wind-tunnel experiments were conducted in the larger test section (test Section I) with dimensions of 17.0 mˆ3.0 mˆ1.7 m in the streamwise (x), spanwise (y) and vertical (z) directions, respectively. The wind tunnel in MHI is 25.0 mˆ3.0 mˆ2.0 m in the x, y and z directions, respectively [8]. The instantaneous velocity was measured by laser Doppler velocimetry in the CRIEPI experiments and hot wire anemometry in the MHI experiments.…”
Section: Wind-tunnel Experimentsmentioning
confidence: 99%
“…This could be due to the negative pressure field in the leeward of the truck cabin, which draws the plume downward. x'=20 inches, Eqn (4)(5)(6)(7)(8)(9)(10)(11)(12) x'=20 inches, Test…”
Section: Plume Centerline and Plume Risementioning
confidence: 99%
“…x'=80 inches, Eqn (4)(5)(6)(7)(8)(9)(10)(11)(12) x'=80 inches, Test The PM sampling instrumentations used in these tests included MOUDI, PM 2.5 , PM 1.0 cyclones, and total PM sampling system. However, it was necessary to establish size-selective sampling of PM with a MOUDI from natural gas vehicles.…”
Section: Plume Centerline and Plume Risementioning
confidence: 99%