1990
DOI: 10.2118/19308-pa
|View full text |Cite
|
Sign up to set email alerts
|

A Newly Developed Chromium(lll) Gel Technology

Abstract: Laboratory testing of a recently developed chromium(III) [Cr(lll)] gel technology is reported. The gels can be used in conjunction with a number of oilfield treatments. The single-fluid acrylamide-polymer/Cr(lll)-carboxylate aqueous gels are formed by crosslinking acrylamide polymer with a Cr(lII)-carboxylate-complex crosslinking agent. Representative gel compositions and associated gel properties are discussed. IntroductionA single-fluid Cr(Ill) gel technology has been developed in which aqueous gels are form… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
116
0

Year Published

1996
1996
2022
2022

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 224 publications
(118 citation statements)
references
References 6 publications
2
116
0
Order By: Relevance
“…The rheological properties such as gelation time measurements were estimated by a visual bottle test method (Sydansk 1990). The bottle test method is a semiquantitative measurement of gelation time, and it can also be considered as a fast and inexpensive method to study the gelation kinetics over a wide range of chemical formulations (Dai et al 2014;Yadav and Mahto 2012).…”
Section: Determination Of Gelation Timementioning
confidence: 99%
“…The rheological properties such as gelation time measurements were estimated by a visual bottle test method (Sydansk 1990). The bottle test method is a semiquantitative measurement of gelation time, and it can also be considered as a fast and inexpensive method to study the gelation kinetics over a wide range of chemical formulations (Dai et al 2014;Yadav and Mahto 2012).…”
Section: Determination Of Gelation Timementioning
confidence: 99%
“…In this case, the acetate in the crosslinker buffers the gelant (originally at pH 6) and makes the gelation reaction less sensitive to pH. [15][16][17] In other words, the acetate buffer tends to counteract the pH-increasing effect of carbonate dissolution. However, the acetate's buffering action may not always be sufficient, especially if the buffer concentration is not high enough.…”
Section: Behavior Of Freshly Prepared Gelants In Fracturesmentioning
confidence: 99%
“…The gel strength was expressed in alphabetic code of A through J according to Syndansk's strength code as shown in Table 2. [24] The gelation behavior of optimum gel formation (polymer concentration: 9903 ppm and crosslinker/polymer ratio: 0.36) was studied using a Bohlin Gemini II rheometer (Malvern Instruments, Malvern, UK). The mechanical strength of the gel can be estimated by its viscoelastic properties such as elastic modulus (G′) and viscous modulus (G′′).…”
Section: Characterization Of Graft Copolymermentioning